Abstract
Purpose Retraction of the left lobe of the liver is an important step in most bariatric surgical procedures. The left lobe of the liver may be enlarged, and laceration, hematoma, or necrosis may develop in the liver due to retraction. In this study, the results of use of the Nathanson retractor (NR) and PretzelFlex retractor (PFR) in the patients undergoing laparoscopic sleeve gastrectomy (LSG) were compared. Materials and Methods The patients who underwent LSG were divided into three groups based on the type of liver retraction device used. Group 1: NR was used fixed during the operation; Group 2: PF retractor was used; Group 3: NR were used only for fundus dissection and when necessary. All groups were evaluated in terms of demographic characteristics, liver function tests, and developing complications. Results The study was conducted with a total of 120 consecutive patients. Operation time in the second group was found to be significantly lower than the other two groups (p = 0.009; p = 0.001; p < 0.01). The duration of retractor use in the first group was significantly higher than the other two groups (p = 0.001; p = 0.001; p < 0.01). While aspartate aminotransferase (AST) values were found to be high in Group 1, alanine aminotransferase (ALT) values were found to be high in Groups 1 and 3. Conclusion PFR has shorter operating and retraction times. It causes less measurable liver damage. Although the NR will be used, intermittent use causes less damage to the liver as in PFR. Graphical abstract

This publication has 23 references indexed in Scilit: