Innovations in atrial fibrillation ablation
Authors:
- 11 April 2022
- journal article
- review article
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 66 (3) , 737-756
Abstract
Background Catheter-based ablation to perform pulmonary vein isolation (PVI) has established itself as a mainstay in the rhythm control strategy of atrial fibrillation. This review article aims to provide an overview of recent advances in atrial fibrillation ablation technology. Methods We reviewed the available literature and clinical trials of innovations in atrial fibrillation ablation technologies including ablation catheter designs, alternative energy sources, esophageal protection methods, electroanatomical mapping, and novel ablation targets. Results Innovative radiofrequency (RF) catheter designs maximize energy delivery while avoiding overheating associated with conventional catheters. Single-shot balloon catheters in the form of cryoballoons, radiofrequency, and laser balloons have proven effective at producing pulmonary vein isolation and improving procedural efficiency and reproducibility. Pulsed field ablation (PFA) is a highly anticipated novel nonthermal energy source under development, which demonstrates selective ablation of the myocardium, producing durable lesions while also minimizing collateral damage. Innovative devices for esophageal protection including esophageal deviation and cooling devices have been developed to reduce esophageal complications. Improved electroanatomical mapping systems are being developed to help identify additional non-pulmonary triggers, which may benefit from ablation, especially with persistent atrial fibrillation. Lastly, the vein of Marshall alcohol ablation has been recently studied as an adjunct therapy for improving outcomes with catheter ablation for persistent atrial fibrillation. Conclusions Numerous advances have been made in the field of atrial fibrillation ablation in the past decade. While further long-term data is still needed for these novel technologies, they show potential to improve procedural efficacy and safety.Keywords
This publication has 137 references indexed in Scilit:
- Fatal End of a Safety Algorithm for Pulmonary Vein Isolation With Use of High-Intensity Focused UltrasoundCirculation: Arrhythmia and Electrophysiology, 2010
- Pulmonary vein isolation with high-intensity focused ultrasound: results from the HIFU 12F studyEP Europace, 2009
- Feasibility of the Radiofrequency Hot Balloon Catheter for Isolation of the Posterior Left Atrium and Pulmonary Veins for the Treatment of Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2009
- Esophageal Injury and Temperature Monitoring During Atrial Fibrillation AblationCirculation: Arrhythmia and Electrophysiology, 2008
- Pulmonary vein isolation by high-intensity focused ultrasound: First-in-man study with a steerable balloon catheterHeart Rhythm, 2007
- Mechanical Esophageal Deflection During Ablation of Atrial FibrillationPacing and Clinical Electrophysiology, 2006
- Myocardial Lesion Formation Using High-intensity Focused UltrasoundJournal of the American Society of Echocardiography, 2006
- Usefulness of a New Radiofrequency Thermal Balloon Catheter for Pulmonary Vein Isolation:Journal of Cardiovascular Electrophysiology, 2003
- Electrical Remodeling of the Atrium in an Anatomic Model of Atrial FlutterCirculation, 2002
- Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary VeinsThe New England journal of medicine, 1998