Abstract
The influence of moisture in vacuum insulation panels (VIPs), with fumed silica kernels, on their thermal conductivity has been investigated. The VIPs are produced with different water contents. The thermal conductivities at different water contents are measured under stationary conditions in a hot-plate apparatus with an average temperature of 10°C (plate temperatures are 0 and 20°C). The increase in thermal conductivity is approximately proportional to the water content. The increase is ≈0.5 × 10 -3 W/(m K) per mass% of water. For typical middle European climate, a maximum moisture content of ≈6 mass% can be expected, which corresponds to a maximum increase of thermal conductivity of ≈3 × 10 -3 W/(m K) for VIPs with fumed silica kernels.Keywords
This publication has 4 references indexed in Scilit:
- Predictions for the Increase in Pressure and Water Content of Vacuum Insulation Panels (VIPs) Integrated into Building Constructions using Model CalculationsJournal of Thermal Envelope and Building Science, 2005
- Permeation of Different Gases Through Foils used as Envelopes for Vacuum Insulation PanelsJournal of Thermal Envelope and Building Science, 2005
- Wärme- und Kälteschutz1995