Evaluation of various deformable image registration algorithms for thoracic images
Authors:
Open Access
- 17 July 2013
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 55 (1) , 175-182
Abstract
We evaluated the accuracy of one commercially available and three publicly available deformable image registration (DIR) algorithms for thoracic four-dimensional (4D) computed tomography (CT) images. Five patients with esophagus cancer were studied. Datasets of the five patients were provided by DIR-lab (dir-lab.com) and consisted of thoracic 4D CT images and a coordinate list of anatomical landmarks that had been manually identified. Expert landmark correspondence was used for evaluating DIR spatial accuracy. First, the manually measured displacement vector field (mDVF) was obtained from the coordinate list of anatomical landmarks. Then the automatically calculated displacement vector field (aDVF) was calculated by using the following four DIR algorithms: B-spine implemented in Velocity AI (Velocity Medical, Atlanta, GA, USA), free-form deformation (FFD), Horn–Schunk optical flow (OF) and Demons in DIRART of MATLAB software. Registration error is defined as the difference between mDVF and aDVF. The mean 3D registration errors were 2.7 ± 0.8 mm for B-spline, 3.6 ± 1.0 mm for FFD, 2.4 ± 0.9 mm for OF and 2.4 ± 1.2 mm for Demons. The results showed that reasonable accuracy was achieved in B-spline, OF and Demons, and that these algorithms have the potential to be used for 4D dose calculation, automatic image segmentation and 4D CT ventilation imaging in patients with thoracic cancer. However, for all algorithms, the accuracy might be improved by using the optimized parameter setting. Furthermore, for B-spline in Velocity AI, the 3D registration error was small with displacements of less than ∼10 mm, indicating that this software may be useful in this range of displacements.Keywords
This publication has 24 references indexed in Scilit:
- Investigation of four‐dimensional (4D) Monte Carlo dose calculation in real‐time tumor tracking stereotatic body radiotherapy for lung cancersMedical Physics, 2012
- Investigation of four-dimensional computed tomography-based pulmonary ventilation imaging in patients with emphysematous lung regionsPhysics in Medicine & Biology, 2011
- Results of a Multi-Institution Deformable Registration Accuracy Study (MIDRAS)International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Four-dimensional deformable image registration using trajectory modelingPhysics in Medicine & Biology, 2009
- Implementation and evaluation of various demons deformable image registration algorithms on a GPUPhysics in Medicine & Biology, 2009
- A framework for evaluation of deformable image registration spatial accuracy using large landmark point setsPhysics in Medicine & Biology, 2009
- Objective assessment of deformable image registration in radiotherapy: A multi‐institution studyMedical Physics, 2008
- Validation of an accelerated ‘demons’ algorithm for deformable image registration in radiation therapyPhysics in Medicine & Biology, 2005
- PET-CT image registration in the chest using free-form deformationsIEEE Transactions on Medical Imaging, 2003