In vitro fatigue tests and in silico finite element analysis of dental implants with different fixture/abutment joint types using computer-aided design models
- 1 January 2018
- journal article
- research article
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 62 (1) , 24-30
Abstract
The aim of this study was to evaluate fatigue resistance of dental fixtures with two different fixture-abutment connections by in vitro fatigue testing and in silico three-dimensional finite element analysis (3D FEA) using original computer-aided design (CAD) models. Dental implant fixtures with external connection (EX) or internal connection (IN) abutments were fabricated from original CAD models using grade IV titanium and step-stress accelerated life testing was performed. Fatigue cycles and loads were assessed by Weibull analysis, and fatigue cracking was observed by micro-computed tomography and a stereomicroscope with high dynamic range software. Using the same CAD models, displacement vectors of implant components were also analyzed by 3D FEA. Angles of the fractured line occurring at fixture platforms in vitro and of displacement vectors corresponding to the fractured line in silico were compared by two-way ANOVA. Fatigue testing showed significantly greater reliability for IN than EX (p<0.001). Fatigue crack initiation was primarily observed at implant fixture platforms. FEA demonstrated that crack lines of both implant systems in vitro were observed in the same direction as displacement vectors of the implant fixtures in silico. In silico displacement vectors in the implant fixture are insightful for geometric development of dental implants to reduce complex interactions leading to fatigue failure.Keywords
This publication has 31 references indexed in Scilit:
- A three-dimensional finite element analysis of the stress distribution on morse taper implants surfaceJournal of Prosthodontic Research, 2013
- Mechanical Testing of Implant-Supported Anterior Crowns with Different Implant/Abutment ConnectionsThe International Journal of Oral and Maxillofacial Implants, 2013
- Removal of Fractured Dental Implant Screw Using a New Technique: A Case ReportJournal of Oral Implantology, 2012
- Influences of implant neck design and implant–abutment joint type on peri-implant bone stress and abutment micromovement: Three-dimensional finite element analysisDental Materials, 2012
- Biomechanical evaluation of internal and external hexagon platform switched implant-abutment connections: An in vitro laboratory and three-dimensional finite element analysisDental Materials, 2012
- Influence of implant neck design and implant–abutment connection type on peri‐implant health. Radiological studyClinical Oral Implants Research, 2012
- Nonlinear finite element analysis of three implant–abutment interface designsInternational Journal of Oral Science, 2012
- Effect of implant connection and restoration design (screwed vs. cemented) in reliability and failure modes of anterior crownsEuropean Journal of Oral Sciences, 2011
- Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogsClinical Oral Implants Research, 2008
- Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationaleClinical Oral Implants Research, 2004