Interfragmentary Suture Fixation for Displaced Acute Type II Distal Clavicle Fractures
- 1 November 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 28 (11) , 653-658
Abstract
Objectives: Stable fixation of displaced type II distal clavicle fractures presents a challenge to the surgeon because of distal fragment comminution and the large deforming forces created by the weight of the arm. We hypothesized that suture fixation around the coracoid and interfragmentary suture fixation would adequately counteract these forces and lead to a high rate of union and restoration of function. Design: This is a retrospective study of 20 sequential patients treated between 1997 and 2009. Setting: In-patient operating room followed by the clinic. Patients/Participants: All patients presenting with acute displaced distal clavicle fractures to 2 surgeons were included. All patients completed the study without loss to follow-up. Intervention: Open repair was performed by placing two #5 Fiberwire sutures around the coracoid and through drill holes in the clavicular shaft. Interfragmentary fixation was performed with figure-of-eight #2 Fiberwire sutures. Main Outcome Measures: Patients evaluation included the American Shoulder and Elbow Surgeons scale, range of motion, radiographic evaluation, and patient satisfaction. Results: All fractures healed without loss of reduction at an average of 2.6 months, and all patients were satisfied. American Shoulder and Elbow Surgeons score was 98.5 out of 100. Average follow-up was 7.1 years (range, 3.1–14.3 years). One postoperative wound hematoma and one superficial wound infection were treated nonoperatively. Conclusions: Interfragmentary and coracoclavicular suture fixation for displaced acute distal clavicle fractures is a safe and effective treatment with an excellent union rate, low complication rate, and high patient satisfaction. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.Keywords
This publication has 21 references indexed in Scilit:
- Results of surgical treatment for unstable distal clavicular fracturesJournal of Shoulder and Elbow Surgery, 2010
- Transacromial erosion of a locked subacromial hook plate: Case report and review of literatureJournal of Shoulder and Elbow Surgery, 2010
- Treatment of unstable distal clavicle fractures using two suture anchors and suture tension bandsInjury, 2009
- The Clavicle Hook Plate for Neer Type II Lateral Clavicle FracturesJournal of Orthopaedic Trauma, 2009
- Migration of a Kirschner Wire From the Clavicle Into the Intrathoracic TracheaThe Annals of Thoracic Surgery, 2009
- Treatment of distal clavicle fractures using an arthroscopic techniqueJournal of Shoulder and Elbow Surgery, 2008
- A method for internal fixation of unstable distal clavicle fractures: Early observations using a new techniqueJournal of Shoulder and Elbow Surgery, 2008
- Surgical treatment of unstable fractures of the distal clavicle: A comparative study of Kirschner wire and clavicular hook plate fixationActa Orthopaedica, 2002
- Treatment of unstable distal clavicular fractures with and without lesions of the acromioclavicular jointInjury, 1996
- FRACTURE OF THE DISTAL CLAVICLE WITH DETACHMENT OF THE CORACOCLAVICULAR LIGAMENTS IN ADULTS1963