Improved Uranium Isotope Ratio Analysis in Liquid Sampling–Atmospheric Pressure Glow Discharge/Orbitrap FTMS Coupling through the Use of an External Data Acquisition System
- 1 April 2021
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 32 (5) , 1224-1236
Abstract
Isotope ratio (IR) analysis of natural abundance uranium presents a formidable challenge for mass spectrometry (MS): the required spectral dynamic range needs to enable the quantitatively accurate measurement of the 234UO2 species present at ∼0.0053% isotopic abundance. We address this by empowering a benchtop Orbitrap Fourier transform mass spectrometer (FTMS) coupled with the liquid sampling–atmospheric pressure glow discharge (LS-APGD) ion source and an external high-performance data acquisition system, FTMS Booster X2. The LS-APGD microplasma has demonstrated impressive capabilities regarding elemental and IR analysis when coupled with Orbitrap FTMS. Despite successes, there are limitations regarding the dynamic range and mass resolution that stem from space charge effects and data acquisition and processing restrictions. To overcome these limitations, the FTMS Booster was externally interfaced to an LS-APGD Q Exactive Focus Orbitrap FTMS to obtain time-domain signals (transients) and to process unreduced data. The unreduced time-domain data acquisition with user-controlled processing permit the evaluation of the effects of in-hardware transient phasing, increased transient lengths, advanced transient coadding, varying the length of a transient to be processed with a user-defined time increment, and the use of absorption-mode FT (aFT) processing methods on IR analysis. The added capabilities extend the spectral dynamic range of the instrument to at least 4–5 orders of magnitude and provide a resolution improvement from ∼70k to 900k m/Δm at 200 m/z. The empowered LS-APGD Orbitrap platform allows for the simultaneous measurement of 234UO2 and the prominent 235UO2 and 238UO2 isotopic species at their natural abundances, ultimately yielding improvements in performance when compared to previous uranium IR results on this same Q Exactive Focus instrument.Keywords
This publication has 52 references indexed in Scilit:
- Optimization of uranium and plutonium separations using TEVA and UTEVA cartridges for MC-ICP-MS analysis of environmental swipe samplesTalanta, 2019
- Static, Mixed-Array Total Evaporation for Improved Quantitation of Plutonium Minor Isotopes in Small SamplesJournal of the American Society for Mass Spectrometry, 2016
- Accurate and precise determination of isotopic ratios by MC‐ICP‐MS: A reviewMass Spectrometry Reviews, 2009
- Assessment of plutonium measurement in the femtogram range by ICP-MS; correction from interfering polyatomic speciesJournal of Analytical Atomic Spectrometry, 2007
- Capillary electrophoresis–high resolution sector field inductively coupled plasma mass spectrometryJournal of Chromatography A, 2007
- Microplasmas for chemical analysis: analytical tools or research toys?Spectrochimica Acta Part B: Atomic Spectroscopy, 2004
- Improved techniques for high accuracy isotope ratio measurements of nuclear materials using thermal ionization mass spectrometryInternational Journal of Mass Spectrometry, 2003
- Sector field mass spectrometers in ICP-MSSpectrochimica Acta Part B: Atomic Spectroscopy, 1998
- Precision and accuracy in isotope ratio measurements by plasma source mass spectrometryJournal of Analytical Atomic Spectrometry, 1998
- High-precision isotopic analyses of uranium and plutonium by total sample volatilization and signal integrationInternational Journal of Mass Spectrometry and Ion Processes, 1991