Characterization of Indoor Air Quality on a College Campus: A Pilot Study
Open Access
- 30 July 2019
- journal article
- research article
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 16 (15) , 2721
Abstract
Recent construction trends on college campuses have demonstrated a shift to designing buildings with features focused on sustainability. However, few studies have investigated indoor air quality in institutions of higher education, particularly in sustainably designed buildings. The objective of this study was to evaluate the association of building and occupancy on indoor air quality within and between higher education buildings. We measured particulate matter, formaldehyde, carbon dioxide, and nitrogen oxides in LEED certified, retrofitted, and conventional building types on a college campus. Three size fractions of particulate matter were measured in each building. We conducted multi-zonal, 48-h measurements when the buildings were occupied and unoccupied. Outdoor particulate matter was significantly higher (PM2.5 = 4.76, PM4 = 17.1, and PM100 = 21.6 µg/m3) than in classrooms (PM2.5 = 1.7, PM4 = 4.2, and PM100 = 6.7 µg/m3) and common areas (PM2.5 = 1.3, PM4 = 4.2, and PM100 = 4.8 µg/m3; all p < 0.001). Additionally, concentrations of carbon dioxide and particulate matter were significantly higher (p < 0.05) during occupied sampling. The results suggest that occupancy status and building zone are major predictors of indoor air quality in campus buildings, which can, in turn, increase the concentration of contaminants, potentially impacting occupant health and performance. More research is warranted to reveal building features and human behaviors contributing to indoor exposures.Keywords
Funding Information
- U.S. Environmental Protection Agency (RD-835635)
This publication has 39 references indexed in Scilit:
- Is CO 2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO 2 Concentrations on Human Decision-Making PerformanceEnvironmental Health Perspectives, 2012
- Student learning performance and indoor environmental quality (IEQ) in air-conditioned university teaching roomsBuilding and Environment, 2012
- Influence of a portable air treatment unit on health-related quality indicators of indoor air in a classroomJournal of Environmental Monitoring, 2011
- Respiratory symptoms, perceived air quality and physiological signs in elementary school pupils in relation to displacement and mixing ventilation system: an intervention studyIndoor Air, 2011
- Respiratory Health Effects of Exposure to Low-NO x Unflued Gas Heaters in the Classroom: A Double-Blind, Cluster-Randomized, Crossover StudyEnvironmental Health Perspectives, 2010
- Indoor Environmental Quality in LEED-Certified Buildings in the U.S.Journal of Asian Architecture and Building Engineering, 2008
- Occupational rhinitisAllergy, 2008
- Concentrations and determinants of gaseous aldehydes in 162 homes in Strasbourg (France)Atmospheric Environment, 2008
- A RECOMMENDED OCCUPATIONAL EXPOSURE LIMIT FOR FORMALDEHYDE BASED ON IRRITATIONJournal of Toxicology and Environmental Health, 1997
- Nitrogen dioxide inside and outside 137 homes and implications for ambient air quality standards and health effects researchEnvironmental Science & Technology, 1983