A specific radioimmunoassay for 5′‐deoxyadenosyl cobalamin in serum
Authors:
- 1 August 1988
- journal article
- research article
- Published by Wiley in British Journal of Haematology
- Vol. 69 (4) , 551-557
Abstract
A specific radioimmunoassay for 5''-deoxyadenosyl cobalamin (ado-Cbl) has been developed using an antiserum raised to this cobalamin (Cbl). At a 1:100 or greater dilution the antiserum did not bind radiolabelled methyl-hydroxo-, sulphito- or cyano-Cbl and these Cbl analogues did not compete in the radioimmunoassay even at 100-fold higher concentration. The serum concentration (range and mean .+-. SD) of ado-Cbl in 30 normal subjects was 47-134 and 81 .+-. 16 pg/ml. The corresponding values for total Cbl in these sera were 189-610 and 355 .+-. 144 pg/ml, and the computed values for methyl-Cbl were 142-476 and 274 .+-. 127 pg/ml. The coefficient of variation was substantially greater for methyl-Cbl than for ado-Cbl (46% v. 21%, respectively). The ado-Cbl concentration was in the normal range (75-95 pg/ml) in five healthy subjects with a low normal concentration (189-217 pg/ml) of total Cbl. In two subjects with low total Cbl (118 and 170 pg/ml) and without any clinical evidence of Cbl deficiency, ado-Cbl was normal (63 and 95 pg/ml, respectively. Thus, in this group, low methyl-Cbl accounted for the lower total Cbl. The concentration (mean .+-. SD) of serum ado-Cbl and methyl-Cbl in six patients with low total Cbl (57 .+-. 25 pg/ml) and clinical evidence for Cbl deficiency was 35 .+-. 12 pg/ml and 22 .+-. 22 pg/ml, respectively. This difference from the normal mean for each cofactor was highly significant (P < 0.001). The decrease in the concentration of methyl-Cbl in Cbl deficiency was relatively greater than the decrease in ado-Cbl (92% v. 57%, respectively) which raised the relative concentration of ado-Cbl in Cbl deficiency to 61% of the total Cbl. Although a low serum methyl-Cbl is a sensitive indicator of Cbl deficiency, it may not be as specific as a decrease in serum ado-Cbl. Factor(s) other than tissue stores of Cbl may lower serum methyl-Cbl below the 95% confidence limit in the absence of clinical Cbl deficiency.Keywords
This publication has 18 references indexed in Scilit:
- FALSE LOW SERUM VITAMIN B12 VALUES WITH RADIODILUTION ASSAYS USING BLOCKED R-BINDERSThe Lancet, 1983
- The Natural History of the Inherited Methylmalonic AcidemiasNew England Journal of Medicine, 1983
- Rapid analysis of cobalamin coenzymes and related corrinoid analogs by high-performance liquid chromatographyAnalytical Biochemistry, 1982
- Interrelationships between Vitamin B12 and Folic Acid in Myelomatosis: Cobalamin Coenzyme and Tetrahydrofolic Acid FunctionScandinavian Journal of Haematology, 1978
- Isolation of 57Co-cobalamin coenzymes at high specific activity from Streptomyces griseusJournal of Chromatography A, 1978
- Tissue distribution of endogenous cobalamins and other corrins in the rat, cat and guinea pigBiochimica et Biophysica Acta (BBA) - General Subjects, 1976
- Cobalamins in human pregnancy and lactationJournal of Clinical Pathology, 1971
- A two-dimensional chromato-bioautographic method for complete separation of individual plasma cobalamins.Journal of Clinical Pathology, 1970
- Patterns of plasma cobalamins in control subjects and in cases of vitamin B12 deficiencyJournal of Clinical Pathology, 1969
- Effect of Deoxyuridine on Incorporation of Tritiated Thymidine: Difference Between Normoblasts and MegaloblastsActa Medica Scandinavica, 1964