GO/Cysteamine-Modified Screen-Printed Carbon Electrode for Square-Wave Anodic Stripping Voltammetric Determination of Cadmium in Fortified Mango and Avocado Digestates
Authors:
- Miguel Angel Lozada RufinoMRMiguel Angel Lozada Rufino
- Eulogia Isabel Zapata PeñaEPEulogia Isabel Zapata Peña
- Gonzalo Manuel Delgado ValdiviezoGVGonzalo Manuel Delgado Valdiviezo
- Rosa Gisela Ortiz CastilloRCRosa Gisela Ortiz Castillo
- Grecia Xiomara Herrera GavilanGGGrecia Xiomara Herrera Gavilan
- David César Ardiles SaraviaDSDavid César Ardiles Saravia
- Luis Alfredo Espinoza-EspinozaLELuis Alfredo Espinoza-Espinoza
- Karina Silvana Gutiérrez-ValverdeKGKarina Silvana Gutiérrez-Valverde
Open Access
- 29 September 2026
- journal article
- research article
- Published by MDPI AG in Biosensors
- Vol. 16 (10) , 544
Abstract
Cadmium contamination in fruits is a relevant food-safety concern because of its toxicity, environmental persistence, and potential transfer from agricultural soils to edible plant tissues. This study developed a screen-printed carbon electrode modified with graphene oxide and cysteamine (SPCE/GO–cysteamine) to determine Cd(II) by square-wave anodic stripping voltammetry (SWASV). Two surface-modification routes, GO-cysteamine and GO-rGO-cysteamine, and GO concentrations of 0.1, 0.2, and 0.5 mg mL−1 were compared by cyclic voltammetry. The direct GO-cysteamine route at 0.2 mg mL−1 produced the highest CV response among the tested conditions and was selected for Cd(II) determination. Raman spectroscopy FTIR spectroscopy and scanning electron microscopy were used to characterize the graphene-based materials employed during surface optimization. Cd(II) concentrations from 1 to 10 µg L−1 were experimentally evaluated; with a calculated LOQ of 0.74 µg L−1, the entire experimentally evaluated range of 1–10 µg L−1, with a sensitivity of 11.30 µA (µg L−1)−1, R2 = 0.9892, a limit of detection of 0.25 µg L−1 and a limit of quantification of 0.74 µg L−1. Fortified Kent mango and Hass avocado digestates also showed concentration-dependent responses, with R2 values of 0.9799 and 0.9788, respectively, and relative standard deviations below 5%. These results demonstrate the feasibility of the SPCE/GO–cysteamine platform for Cd(II) determination in digested fruit matrices and support its further development as a portable screening approach for food-quality control.Keywords
All Related Versions
Funding Information
- National University of Frontera (002-2025-UNF)
This publication has 31 references indexed in Scilit:
- Electrochemical Sensors for Heavy Metal Ion Detection in Aqueous Medium: A Systematic ReviewACS Omega, 2024
- Thiol-based chemically modified carbon screen-printed electrode for simultaneous quantification of trace level Pb(II) and Cd(II)Analytical Sciences, 2024
- Recent advances on Raman spectroscopy of graphene: towards biosensing applicationsMaterials Chemistry and Physics, 2024
- The innovative and accurate detection of heavy metals in foods: A critical review on electrochemical sensorsFood Control, 2023
- Analysis of physicochemical attributes, contamination level of trace metals and assessment of health risk in mango fruits from Southern region EthiopiaToxicology Reports, 2023
- Electrochemically reduced graphene oxide: Preparation, composites, and applicationsCarbon, 2022
- Impact of cadmium pollution on food safety and human healthCurrent Opinion in Toxicology, 2021
- Sensory development for heavy metal detection: A review on translation from conventional analysis to field-portable sensorTrends in Food Science & Technology, 2021
- Inexpensive and green electrochemical sensor for the determination of Cd(II) and Pb(II) by square wave anodic stripping voltammetry in bivalve mollusksFood Chemistry, 2020
- Sensitive Stripping Determination of Cadmium(II) and Lead(II) on Disposable Graphene Modified Screen‐Printed ElectrodeElectroanalysis, 2013