Development of a time-cycled volume-controlled pressure-limited respirator and lung mechanics system for total liquid ventilation
Authors:
- J.L. LarrabeJLJ.L. Larrabe
- F.J. AlvarezFAF.J. Alvarez
- E.G. CuestaECE.G. Cuesta
- A. Valls-I-SolerAVA. Valls-I-Soler
- L.E. AlfonsoLAL.E. Alfonso
- A. ArnaizAAA. Arnaiz
- M.B. FernandezMFM.B. Fernandez
- B. LoureiroBLB. Loureiro
- N.G. PublicoverNPN.G. Publicover
- L. RomanLRL. Roman
- J.A. CaslaJCJ.A. Casla
- M.A. GomezMGM.A. Gomez
- 1 January 2001
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 48 (10) , 1134-1144
Abstract
Total liquid ventilation can support gas exchange in animal models of lung injury. Clinical application awaits further technical improvements and performance verification. Our aim was to develop a liquid ventilator, able to deliver accurate tidal volumes, and a computerized system for measuring lung mechanics. The computer-assisted, piston-driven respirator controlled ventilatory parameters that were displayed and modified on a real-time basis. Pressure and temperature transducers along with a lineal displacement controller provided the necessary signals to calculate lung mechanics, Ten newborn lambs (<6 days old) with respiratory failure induced by lung lavage, were monitored using the system. Electromechanical, hydraulic, and data acquisition/analysis components of the ventilator were developed and tested in animals with respiratory failure. All pulmonary signals were collected synchronized in time, displayed in real-time, and archived on digital media. The total mean error (due to transducers, analog-to-digital conversion, amplifiers, etc.) was less than 5% compared with calibrated signals. Components (tubing, pistons, etc.) in contact with exchange fluids were developed so that they could be readily switched, a feature that will be important In clinical settings. Improvements in gas exchange and lung mechanics were observed during liquid ventilation, without impairment of cardiovascular profiles. The total liquid ventilator maintained accurate control of tidal volumes and the sequencing of inspiration/expiration. The computerized system demonstrated its ability to monitor in vivo lung mechanics, providing valuable data for early decision making.Keywords
This publication has 29 references indexed in Scilit:
- Development and application of a double-piston configured, total-liquid ventilatory support deviceCritical Care Medicine, 2000
- Evaluation of gas exchange, pulmonary compliance, and lung injury during total and partial liquid ventilation in the acute respiratory distress syndromeCritical Care Medicine, 1996
- The effects of multiple small doses of exogenous surfactant on experimental respiratory failure induced by lung lavage in ratsActa Anaesthesiologica Scandinavica, 1995
- Development and application of a simplified liquid ventilatorCritical Care Medicine, 1995
- Liquid Ventilation Improves Pulmonary Function, Gas Exchange, and Lung Injury in a Model of Respiratory FailureAnnals of Surgery, 1995
- Evaluation of neonatal pulmonary mechanics and energetics: A two factor least mean square analysisPediatric Pulmonology, 1988
- Effect of Liquid Ventilation on Preterm Lamb Tracheal MechanicsNeonatology, 1983
- In Vivo Lung Lavage as an Experimental Model of the Respiratory Distress SyndromeActa Anaesthesiologica Scandinavica, 1980
- The Continuous Measurement of Pulmonary Gas Exchange and MechanicsThe Annals of Thoracic Surgery, 1972
- Survival of Mammals Breathing Organic Liquids Equilibrated with Oxygen at Atmospheric PressureScience, 1966