Surgical repair of the distal biceps brachii tendon: a comparative study of three surgical fixation techniques
- 29 June 2011
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 19 (11) , 1936-1941
Abstract
Purpose: Several fixation techniques exist to repair the distal biceps brachii tendon. We aimed to evaluate the clinical and functional outcomes after distal biceps tendon repair using three different fixation techniques.Methods: A total of 54 patients were included in the study and were available for follow‐up (mean, 30.7 months; SD 18.6). Surgery was performed using a single‐incision approach with Corkscrews or Mitek suture anchors or with a two‐incision exposure using transosseous sutures. The patients were evaluated with range of motion (ROM) measurements for flection/extension and pronation/supination as well as Disabilities of Arm Shoulder and Hand (DASH) scores. Furthermore, the duration of surgery and the length of hospital stay as well as the complication rate were analyzed.Results: Fifty‐four out of 73 patients were available after a mean follow‐up time of 30.7 months (SD 18.6) for clinical evaluation. There was no statistical significant difference between the three groups comparing the mean DASH score, the length of hospital stay, the duration of surgery, or the ROM. The most common complication was neurapraxia, with 6 cases. All 3 reruptures were registered in the Mitek anchors group. Two patients in the Mitek anchors group required an open arthrolysis due to stiffness of the elbow.Conclusions: In summary, we achieved good clinical and functional results after surgical repair of the distal biceps tendon using Corkscrews, Mitek anchors, or transosseous sutures. The results conferred by Corkscrews were comparable to the other techniques, justifying their use.Level of evidence: III.Keywords
This publication has 31 references indexed in Scilit:
- Biomechanical Comparison of 4 Double‐Row Suture‐Bridging Rotator Cuff Repair Techniques Using Different Medial‐Row ConfigurationsArthroscopy, 2010
- One- versus Two-Incision Technique for Distal Biceps Tendon RepairHSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery, 2008
- Repair of the Ruptured Distal Biceps TendonThe American Journal of Sports Medicine, 2008
- Interference Screw Versus Suture Anchor Fixation for Subpectoral Tenodesis of the Proximal Biceps Tendon: A Cadaveric StudyArthroscopy, 2008
- Cyclic Loading of Rotator Cuff ReconstructionsThe American Journal of Sports Medicine, 2008
- Patient-oriented functional outcome after repair of distal biceps tendon ruptures using a single-incision techniqueJournal of Shoulder and Elbow Surgery, 2005
- A New TechniqueThe American Journal of Sports Medicine, 2004
- Distal Biceps Tendon RupturesClinical Orthopaedics and Related Research, 2002
- Repair of distal biceps tendon rupture: A new technique using the endobuttonJournal of Shoulder and Elbow Surgery, 2000
- Avulsion of the lower biceps brachii tendonThe American Journal of Surgery, 1941