Enhanced Measurement Stability and Selectivity for Choline and Acetylcholine by Capillary Electrophoresis with Electrochemical Detection at a Covalently Linked Enzyme-Modified Electrode
Authors:
- 7 September 2002
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (20) , 5321-5326
Abstract
Enzyme-modified microelectrodes were developed for the indirect amperometric detection of acetylcholine and choline following separation by capillary electrophoresis. Electrodes were prepared by first sequentially electrodepositing polypyrrole and polytyramine from the monomers on a 200-μm platinum electrode. The polymer bilayer provides enhanced selectivity and pendant amino groups for covalent coupling of acetylcholinesterase (AChE) and choline oxidase (ChO) by their reaction with glutaraldehyde. The AChE/ChO-modified electrode was then employed as an end-column detector to determine acetylcholine and choline with and without the internal standard butyrylcholine. Excellent operational stability during 2 days of continuous use was observed, with detection limits of 2 μM or 50 fmol for both acetylcholine and choline. The response from potential interferences, such as dopamine, catechol, and norepinephrine, were significantly reduced in comparison to a bare platinum electrode. The utility of this approach was demonstrated by monitoring the uptake of choline into synaptosomes.Keywords
This publication has 44 references indexed in Scilit:
- Optimization of amperometric microsensors for monitoring choline in the extracellular fluid of brain tissueAnalytica Chimica Acta, 1995
- Quantitation of Choline in the Extracellular Fluid of Brain Tissue with Amperometric MicrosensorsAnalytical Chemistry, 1994
- Development of Choline and Acetylcholine Pt MicroelectrodesAnalytical Biochemistry, 1993
- Amperometric sensors for peroxide, choline, and acetylcholine based on electron transfer between horseradish peroxidase and a redox polymerAnalytical Chemistry, 1993
- Acetylcholine biosensor involving entrapment of two enzymes. Optimization of operational and storage conditionsAnalytica Chimica Acta, 1992
- Strategies for low detection limit measurements with cyclic voltammetryAnalytical Chemistry, 1991
- Ultramicro acetylcholine sensor based on an enzyme-modified carbon fibre electrodeAnalytica Chimica Acta, 1991
- Development of acetylcholine sensor using carbon fiber (amperometric determination)Biosensors and Bioelectronics, 1991
- Sensitive biosensor for choline and acetylcholine involving fast immobilization of a bienzyme system on a disposable membraneAnalytica Chimica Acta, 1990
- Amperometric acetylcholine and choline sensors with immobilized enzymesAnalytica Chimica Acta, 1986