Dynamics of ablation plume particles generated during excimer laser corneal ablation
Authors:
- 1 January 1995
- journal article
- research article
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 16 (4) , 384-389
Abstract
Background and Objective: Although the empirical characteristics of ArF excimer laser corneal ablation have been well documented, the exact ablation mechanisms are not well understood. The present paper reports a quantitative analysis of corneal ablation plumes using in situ time resolved laser light scattering and Raman spectroscopy. Study Design/Materials and Methods: Bovine corneas were used as the ArF excimer laser ablation targets. Light scattering data were recorded from the ablation plume as a function of height above the tissue surface and as function of delay time with respect to the ablative ArF laser pulse. Results: Raman spectra of the ablation plume allow identification of the particles as water. Mean plume particle diameters are found to decrease with height, while the particle volume fractions are relatively constant. The total volume of plume particles correlates well with the total volume of water in the ablated corneal tissue. Conclusion: The finding of a non-evolving plume composed of water spherules, combined with the excellent agreement between total volume of water in the plume and the content of water in the ablated corneal tissue, support the concept of photodecomposition or “cold ablation” for corneal tissue during ArF excimer laser ablation.Keywords
This publication has 15 references indexed in Scilit:
- The physics of UV laser cornea ablationIEEE Journal of Quantum Electronics, 1991
- Effect of excimer laser radiant exposure on uniformity of ablated corneal surfaceLasers in Surgery and Medicine, 1989
- Mass spectroscopic analysis of excimer laser ablated material from human corneal tissueJournal of Cataract & Refractive Surgery, 1988
- High-Speed Photography of Excimer Laser Ablation of the CorneaArchives of Ophthalmology (1950), 1987
- Quantitative and ultrastructural studies of excimer laser ablation of the cornea at 193 and 248 nanometersLasers in Surgery and Medicine, 1987
- Ablation of Polymers and Biological Tissue by Ultraviolet LasersScience, 1986
- Quantitation of Corneal Ablation by Ultraviolet Laser LightArchives of Ophthalmology (1950), 1985
- Excimer Laser Ablation of the Cornea and LensOphthalmology, 1985
- An experimental investigation into soot formation and distribution in polymer diffusion flamesCombustion and Flame, 1980
- A comparison of numerical solutions to the self-preserving size distribution for aerosol coagulation in the free-molecule regimeJournal of Aerosol Science, 1976