Synchronized Biventricular Heart Pacing in a Closed-chest Porcine Model based on Wirelessly Powered Leadless Pacemakers
Open Access
- 7 February 2020
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-9
Abstract
About 30% of patients with impaired cardiac function have ventricular dyssynchrony and seek cardiac resynchronization therapy (CRT). In this study, we demonstrate synchronized biventricular (BiV) pacing in a leadless fashion by implementing miniaturized and wirelessly powered pacemakers. With their flexible form factors, two pacemakers were implanted epicardially on the right and left ventricles of a porcine model and were inductively powered at 13.56 MHz and 40.68 MHz industrial, scientific, and medical (ISM) bands, respectively. The power consumption of these pacemakers is reduced to µW-level by a novel integrated circuit design, which considerably extends the maximum operating distance. Leadless BiV pacing is demonstrated for the first time in both open-chest and closed-chest porcine settings. The clinical outcomes associated with different interventricular delays are verified through electrophysiologic and hemodynamic responses. The closed-chest pacing only requires the external source power of 0.3 W and 0.8 W at 13.56 MHz and 40.68 MHz, respectively, which leads to specific absorption rates (SARs) 2–3 orders of magnitude lower than the safety regulation limit. This work serves as a basis for future wirelessly powered leadless pacemakers that address various cardiac resynchronization challenges.Keywords
This publication has 38 references indexed in Scilit:
- Cardiac pacing in paediatric patients with congenital heart defects: transvenous or epicardial?EP Europace, 2013
- 2012 EHRA/HRS expert consensus statement on cardiac resynchronization therapy in heart failure: implant and follow-up recommendations and managementHeart Rhythm, 2012
- Incidence and predictors of short- and long-term complications in pacemaker therapy: The FOLLOWPACE studyHeart Rhythm, 2012
- First-in-Human Testing of a Wirelessly Controlled Drug Delivery MicrochipScience Translational Medicine, 2012
- A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose MonitoringIEEE Journal of Solid-State Circuits, 2011
- A Conformal, Bio-Interfaced Class of Silicon Electronics for Mapping Cardiac ElectrophysiologyScience Translational Medicine, 2010
- Wireless Power Transfer via Strongly Coupled Magnetic ResonancesScience, 2007
- Cardiac-Resynchronization Therapy with or without an Implantable Defibrillator in Advanced Chronic Heart FailureNew England Journal of Medicine, 2004
- High intensity focused ultrasound: surgery of the future?British Journal of Radiology, 2003
- Cardiac Resynchronization in Chronic Heart FailureNew England Journal of Medicine, 2002