Abstract
When a total of 1114 rounds of projectiles are fired, the grappling hook of the breechblock and the pin of the locking mechanism break at the place where cartridge case extraction takes place. A method combining experimental test and theoretical analysis is used to analyze the elastic-plastic deformation of the extraction system. The fatigue life of the grappling hook and the pin of the breechblock is calculated to be 1150 rounds. Through comprehensive improved design measures such as improvement of the load transfer path of the locking mechanism, the local structure, the material replacement, and the heat treatment process, the improved simulation results of the locking mechanism show that the fatigue life has reached 15,000 rounds. Up to now, the improved locking mechanism has withstood the failure-free firing of over 8,000 rounds, meeting the requirements of gun reliability indicators.