MR-guided ultrasound-stimulated microbubble therapy enhances radiation-induced tumor response
Open Access
- 18 March 2023
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-10
Abstract
High intensity focused ultrasound (HIFU) systems have been approved for therapeutic ultrasound delivery to cause tissue ablation or induced hyperthermia. Microbubble agents have also been used in combination with sonication exposures. These require temperature feedback and monitoring to prevent unstable cavitation and prevent excess tissue heating. Previous work has utilized lower power and pressure to oscillate microbubbles and transfer energy to endothelial cells in the absence of thermally induced damage that can radiosensitize tumors. This work investigated whether reduced acoustic power and pressure on a commercial available MR-integrated HIFU system could result in enhanced radiation-induced tumor response after exposure to ultrasound-stimulated microbubbles (USMB) therapy. A commercially available MR-integrated HIFU system was used with a hyperthermia system calibration provided by the manufacturer. The ultrasound transducer was calibrated to reach a peak negative pressure of − 750 kPa. Thirty male New Zealand white rabbits bearing human derived PC3 tumors were grouped to receive no treatment, 14 min of USMB, 8 Gy of radiation in a separate irradiation cabinet, or combined treatments. In vivo temperature changes were collected using MR thermometry at the tumor center and far-field muscle region. Tissues specimens were collected 24 h post radiation therapy. Tumor cell death was measured and compared to untreated controls through hematoxylin and eosin staining and immunohistochemical analysis. The desired peak negative pressure of − 750 kPa used for previous USMB occurred at approximately an input power of 5 W. Temperature changes were limited to under 4 °C in ten of twelve rabbits monitored. The median temperature in the far-field muscle region of the leg was 2.50 °C for groups receiving USMB alone or in combination with radiation. Finally, statistically significant tumor cell death was demonstrated using immunohistochemical analysis in the combined therapy group compared to untreated controls. A commercial MR-guided therapy HIFU system was able to effectively treat PC3 tumors in a rabbit model using USMB therapy in combination with radiation exposures. Future work could find the use of reduced power and pressure levels in a commercial MR-guided therapy system to mechanically stimulate microbubbles and damage endothelial cells without requiring high thermal doses to elicit an antitumor response.Keywords
Funding Information
- Terry Fox Foundation
This publication has 32 references indexed in Scilit:
- Enhancing Ablation Effects of a Microbubble-Enhancing Contrast Agent (“SonoVue”) in the Treatment of Uterine Fibroids With High-Intensity Focused Ultrasound: A Randomized Controlled TrialCardioVascular and Interventional Radiology, 2014
- Ultrasound-Mediated Microbubble Enhancement of Radiation Therapy Studied Using Three-Dimensional High-Frequency Power Doppler UltrasoundUltrasound in Medicine & Biology, 2013
- Antitumor Effects of Combining Docetaxel (Taxotere) with the Antivascular Action of Ultrasound Stimulated MicrobubblesPLOS ONE, 2012
- Volumetric MR-HIFU ablation of uterine fibroids: Role of treatment cell size in the improvement of energy efficiencyEuropean Journal of Radiology, 2012
- Tumor radiation response enhancement by acoustical stimulation of the vasculatureProceedings of the National Academy of Sciences, 2012
- Fiji: an open-source platform for biological-image analysisNature Methods, 2012
- Tumour hyperthermia and ablation in rats using a clinical MR‐HIFU system equipped with a dedicated small animal set‐upInternational Journal of Hyperthermia, 2012
- Quantitative MRI-based temperature mapping based on the proton resonant frequency shift: Review of validation studiesInternational Journal of Hyperthermia, 2005
- Radiation and ceramide-induced apoptosisOncogene, 2003
- A. functional MRI technique combining principles of echo‐shifting with a train of observations (PRESTO)Magnetic Resonance in Medicine, 1993