Aliasing Artifacts in Multielemental LA-ICP-TOFMS Mapping: An Old Problem Revisited
Open Access
- 3 June 2026
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (23) , 16813-16818
Abstract
Recent works on quadrupole LA-ICP-MS have shown that unsynchronized laser pulses and data acquisition routines can produce pronounced signal aliasing. This phenomenon appears in the form of long-range and low- to medium-frequency alterations in time-averaged signals that do not reflect the actual underlying analyte concentration distribution, leading to wrong quantitation and considerably deteriorated image quality. In quadrupole instruments, total cycle times, settling and dwell times per nuclide could be finely tuned to match the pulse time of the laser (and/or SPR), thereby eliminating these artifacts. By contrast, in LA-ICP-TOFMS, exact synchronization between the two instrumental components is impossible even in principle. The reason lies in the fact that the acquisition time in the mass analyzer is a constrained value, and can only be set as an integer multiple of base acquisition time of the instrument. As a result, some level of aliasing is inevitable even if the acquisition time is set close to the SPR. In this work, we discuss the choice of optimal acquisition time in TOF instruments. Theoretical simulations and experimental mappings of standard reference materials strongly suggest that a compromise has to be made to minimize the spread of the signal without producing too much redundant data.Keywords
Funding Information
- The Slovenian Research and Innovation Agency (P1-0034)
- The Slovenian Research and Innovation Agency (P2-0152)
This publication has 25 references indexed in Scilit:
- Boosting the Pixel Acquisition Rate of Elemental Mapping with Laser Ablation–ICP-Mass Spectrometry to 1000 HzAnalytical Chemistry, 2025
- Evaluation of two-phase sample transport upon ablation of gelatin as a proxy for soft biological matrices using nanosecond laser ablation – inductively coupled plasma – mass spectrometryAnalytica Chimica Acta, 2023
- LA-ICP-MS imaging in the geosciences and its applications to geochronologyChemical Geology, 2021
- Skip the beat: minimizing aliasing error in LA-ICP-MS measurementsAnalytical and Bioanalytical Chemistry, 2018
- Considerations on data acquisition in laser ablation-inductively coupled plasma-mass spectrometry with low-dispersion interfacesSpectrochimica Acta Part B: Atomic Spectroscopy, 2018
- Fast Chemical Imaging at High Spatial Resolution by Laser Ablation Inductively Coupled Plasma Mass SpectrometryAnalytical Chemistry, 2013
- Applications of laser-ablation-inductively-coupled plasma-mass spectrometry in chemical analysis of forensic evidenceTrAC Trends in Analytical Chemistry, 2013
- Basic Modeling Approach To Optimize Elemental Imaging by Laser Ablation ICPMSAnalytical Chemistry, 2010
- Role of laser ablation–inductively coupled plasma–mass spectrometry in cultural heritage research: A reviewAnalytica Chimica Acta, 2009
- Preliminary Design Considerations and Characteristics of an Inductively Coupled Plasma-Time-of-Flight Mass SpectrometerMicrochemical Journal, 1993