Accounting for variability in ion current recordings using a mathematical model of artefacts in voltage-clamp experiments
Open Access
- 25 May 2020
- journal article
- research article
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 378 (2173) , 20190348
Abstract
Mathematical models of ion channels, which constitute indispensable components of action potential models, are commonly constructed by fitting to whole-cell patch-clamp data. In a previous study, we fitted cell-specific models to hERG1a (Kv11.1) recordings simultaneously measured using an automated high-throughput system, and studied cell-cell variability by inspecting the resulting model parameters. However, the origin of the observed variability was not identified. Here, we study the source of variability by constructing a model that describes not just ion current dynamics, but the entire voltage-clamp experiment. The experimental artefact components of the model include: series resistance, membrane and pipette capacitance, voltage offsets, imperfect compensations made by the amplifier for these phenomena, and leak current. In this model, variability in the observations can be explained by either cell properties, measurement artefacts, or both. Remarkably, by assuming that variability arises exclusively from measurement artefacts, it is possible to explain a larger amount of the observed variability than when assuming cell-specific ion current kinetics. This assumption also leads to a smaller number of model parameters. This result suggests that most of the observed variability in patch-clamp data measured under the same conditions is caused by experimental artefacts, and hence can be compensated for in post-processing by using our model for the patch-clamp experiment. This study has implications for the question of the extent to which cell-cell variability in ion channel kinetics exists, and opens up routes for better correction of artefacts in patch-clamp data. This article is part of the theme issue ‘Uncertainty quantification in cardiac and cardiovascular modelling and simulation’.Keywords
All Related Versions
Funding Information
- Wellcome Trust (101222/Z/13/Z, 212203/Z/18/Z)
- Engineering and Physical Sciences Research Council (EP/L016044/1)
- Biotechnology and Biological Sciences Research Council (BB/P010008/1)
- ZonMw (114022502)
This publication has 46 references indexed in Scilit:
- Application of cardiac electrophysiology simulations to pro‐arrhythmic safety testingBritish Journal of Pharmacology, 2012
- Simulation of the Undiseased Human Cardiac Ventricular Action Potential: Model Formulation and Experimental ValidationPLOS Computational Biology, 2011
- Patch-clamp amplifiers on a chipJournal of Neuroscience Methods, 2010
- Expression and Biophysical Characterization of Voltage-Gated Sodium Channels in Axons and Growth Cones of the Regenerating Optic NerveInvestigative Ophthalmology & Visual Science, 2010
- Population Patch Clamp Improves Data Consistency and Success Rates in the Measurement of Ionic CurrentsSLAS Discovery, 2006
- Temperature dependence of human ether-à-go-go-related gene K+ currentsAmerican Journal of Physiology-Cell Physiology, 2006
- A model for human ventricular tissueAmerican Journal of Physiology-Heart and Circulatory Physiology, 2004
- Series Resistance Compensation for Whole-Cell Patch-Clamp Studies Using a Membrane State EstimatorBiophysical Journal, 1999
- A single electrode voltage, current- and patch-clamp amplifier with complete stable series resistance compensationJournal of Neuroscience Methods, 1995
- Design of the EPC-9, a computer-controlled patch-clamp amplifier. 2. SoftwareJournal of Neuroscience Methods, 1995