Abstract
INTRODUCTION: The goal of this study was to identify nationwide access to transient elastography (TE), magnetic resonance elastography (MRE), and gastroenterologists. METHODS: We used public data from each test's manufacturer's website to identify the number of TE and MRE units in the United States. We used public data from the Health Resources and Services Administration to identify the number of gastroenterologists in the United States. RESULTS: Overall, 82.4% of US counties do not contain TE or MRE, and 69.2% do not contain a gastroenterologist. Two-thirds (67.4%) of US counties do not contain either elastography or a gastroenterologist. DISCUSSION: There is limited access to TE, MRE, and gastroenterologists in the United States.
Funding Information
  • National Institute of Diabetes and Digestive and Kidney Diseases (DK134448)
  • National Center for Advancing Translational Sciences (TL1 TR002380)