Instrumental Parameters in the MALDI-TOF Mass Spectrometric Analysis of Quaternary Protein Structures
Authors:
- 1 December 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (1) , 103-110
Abstract
Several former studies have shown that MALDI-TOF-MS can be applied successfully to investigate the quaternary structure of proteins. Whereas most of these reports were focused on MALDI sample preparation, there is little information about the influence of instrumental parameters on the desorption/ionization and gas-phase behavior of protein subunit assemblies. Therefore, in addition of giving short examples of the quaternary structure analysis of a microheterogeneous glycoprotein, a metalloenzyme, and a heme-binding enzyme by MALDI-TOF-MS, we report a systematic study of the effect of some instrumental parameters on the analysis of chicken egg white avidin. From these tested parameters, only the laser pulse energy was found to influence the relative abundance of the intact assembly as well as the formation of nonspecific cluster ions significantly. This finding suggests that the disruption of the noncovalent interactions during the desorption/ionization process takes place at a very short time interval after the laser ablation, whereas those assemblies that survive this step are rather stable afterward in the gas phase. In addition, we present clear evidence that protein cluster ions are not preformed during sample preparation but originate from nonspecific assemblage during desorption/ionization.Keywords
This publication has 34 references indexed in Scilit:
- Detection of immune complexes by matrix‐assisted laser desorption/ionization mass spectrometryRapid Communications in Mass Spectrometry, 2003
- Oligomerization and substrate binding studies of the adenylate kinase from Sulfolobus acidocaldarius by matrix-assisted laser desorption/ionization mass spectrometryThe Analyst, 2000
- Protein subunit interactions and structural integrity of amyloidogenic transthyretins: evidence from electrospray mass spectrometryJournal of Molecular Biology, 1998
- Characterisation of the heptameric pore‐forming complex of the Aeromonas toxin aerolysin using MALDI‐TOF mass spectrometryFEBS Letters, 1996
- Observation of mixed molecular cluster ions in matrix-assisted UV laser desorption/ionization of high mass protein mixturesInternational Journal of Mass Spectrometry and Ion Processes, 1995
- Matrix Dependence of Metastable Fragmentation of Glycoproteins in MALDI TOF Mass SpectrometryAnalytical Chemistry, 1995
- Principles and applications of matrix-assisted UV-laser desorption/ionization mass spectrometryAnalytica Chimica Acta, 1990
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988
- Acetylated N‐terminal structures of class III alcohol dehydrogenases Differences among the three enzyme classesFEBS Letters, 1987
- The refined structure of beef liver catalase at 2·5 Å resolutionActa crystallographica Section B, Structural science, crystal engineering and materials, 1986