Lower Interbreath Interval Complexity Is Associated With Extubation Failure in Mechanically Ventilated Patients During Spontaneous Breathing Trials
- 1 June 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 68 (6) , 1310-1316
Abstract
Objective: To determine whether lower complexity of interbreath interval as measured with nonlinear analysis techniques will identify patients who fail to separate from mechanical ventilation after 30-minute spontaneous breathing trials (SBTs). Methods: Respiratory waveforms from SBT of patients in surgical or burn intensive care units were recorded for later analysis. The decision to extubate was made by attending physician. Extubated patients were observed for 48 hours; during this time, reintubation or noninvasive positive pressure ventilation was considered as a failure. Analysis of waveform data by software was performed post hoc. Sample entropy (SampEn) and other nonlinear measures were 48 hours of extubation. Results: Thirty-two patients (24 burn, 8 trauma/surgical admissions; mean age, 40.2 ± 16.9 years; 26 men and 6 women) who were intubated >24 hours were extubated after SBT. Twenty-four patients were successfully separated from mechanical ventilation and eight failed. Age, gender, and mechanism of injury did not influence outcome. SampEn calculated for the two groups presented in this study was different with the cohort that failed extubation having a lower mean value (1.35 ± 0.39 vs. 1.87 ± 0.27; p < 0.001). Other nonlinear metrics were moved in concert with SampEn. The stationarity in the respiratory signal was not different between groups. Conclusion: In intubated patients, the interbreath interval in those who were successfully separated from mechanical ventilation was more irregular than those who failed, as measured by nonlinear techniques. When available at bedside, these metrics may be useful markers of pulmonary health and assist in clinical decision making.Keywords
This publication has 58 references indexed in Scilit:
- Reduced breathing variability as a predictor of unsuccessful patient separation from mechanical ventilation*Critical Care Medicine, 2006
- Breathing pattern variability: a weaning predictor in postoperative patients recovering from systemic inflammatory response syndromeIntensive Care Medicine, 2004
- Extubation failure: magnitude of the problem, impact on outcomes, and preventionCurrent Opinion in Critical Care, 2003
- Predicting Success in Weaning From Mechanical VentilationChest, 2001
- Pattern of spontaneous breathing: potential marker for weaning outcomeIntensive Care Medicine, 2000
- Breathing pattern in humans: diversity and individualityRespiration Physiology, 2000
- Approximate entropy of respiratory rate and tidal volume during weaning from mechanical ventilationCritical Care Medicine, 1998
- Effect of Failed Extubation on the Outcome of Mechanical VentilationChest, 1997
- A randomized, controlled trial of protocol-directed versus physician-directed weaning from mechanical ventilationCritical Care Medicine, 1997
- Variability of resting respiratory drive and timing in healthy subjectsJournal of Applied Physiology, 1988