Soft‐start control strategy for the three‐phase grid‐connected inverter with LCL filter
Author:
Open Access
- 1 July 2016
- journal article
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 52 (14) , 1242-1244
Abstract
To solve the start‐up inrush current existing in the three‐phase grid‐connected inverter, a soft‐start control strategy for the three‐phase grid‐connected inverter with LCL filter is proposed. The analysis of start‐up inrush current is illustrated in detail. The capacitor current of the LCL filter is used to detect the closure of the grid‐connected switch, so the closing time of the grid‐connected switch does not need to be known. The detailed procedure and flowchart of the proposed soft‐start control method are provided. Finally, experimental results of a LCL‐type three‐phase grid‐connected inverter verify the theoretical analysis. The control strategy is easy to implement. The start‐up inrush current does not exist in the grid‐connected inverter.Keywords
Funding Information
- National Natural Science Foundation of China (51407153)
This publication has 5 references indexed in Scilit:
- Improved control strategy for the three‐phase grid‐connected inverterIET Renewable Power Generation, 2015
- Stability Improvement of Interleaved Voltage Source Inverters Employing Coupled Inductors for Grid-Connected ApplicationsIEEE Transactions on Industrial Electronics, 2015
- A DC Voltage Monitoring and Control Method for Three-Phase Grid-Connected Wind Turbine InvertersIEEE Transactions on Power Electronics, 2008
- Design and Control of an LCL-Filter-Based Three-Phase Active RectifierIEEE Transactions on Industry Applications, 2005
- An instantaneous active and reactive current component method for active filtersIEEE Transactions on Power Electronics, 2000