PDMS-based conformable microelectrode arrays with selectable novel 3-D microelectrode geometries for surface stimulation and recording
Authors:
- 1 September 2009
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2009 (1094687X) , 1623-1626
Abstract
A method for fabricating polydimethylsiloxane (PDMS) based conformable microelectrode arrays (MEAs) with selectable novel 3-D microelectrode geometries is presented. Simply recessed, conically recessed, exponentially recessed, and protruded-well microelectrodes have been fabricated on the MEA with a diameter as small as 10 mum. 3-D microelectrode geometry parameters (recess depth, recess slope & profile, and protrusion/planar) can be controlled independently during fabrication. Exponentially and conically recessed microelectrodes are promising in chronic stimulation applications, such as neural prostheses, for their production of a uniform current density profile during stimulation, which can minimize stimulation-induced tissue burning and electrode corrosion. Protruded-well microelectrodes potentially provide a closer and sealed contact to the target tissue surface, avoiding current leakage during stimulation and thus achieving better stimulation efficiency in both charge delivery and spatial specificity.Keywords
This publication has 12 references indexed in Scilit:
- A lithographically-patterned, elastic multi-electrode array for surface stimulation of the spinal cordBiomedical Microdevices, 2007
- Fabrication of implantable microelectrode arrays by laser cutting of silicone rubber and platinum foilJournal of Neural Engineering, 2005
- Stretchable micro-electrode arrays for dynamic neuronal recording of in vitro mechanically injured brain2005
- Imaging of Nonuniform Current Density at Microelectrodes by Electrogenerated ChemiluminescenceAnalytical Chemistry, 1999
- Imaging Microelectrodes with High-Frequency Electrogenerated ChemiluminescenceThe Journal of Physical Chemistry B, 1998
- In vitro measurement and characterization of current density profiles produced by nonrecessed, simple recessed, and radially varying recessed stimulating electrodesIEEE Transactions on Biomedical Engineering, 1991
- Charge density and charge per phase as cofactors in neural injury induced by electrical stimulationIEEE Transactions on Biomedical Engineering, 1990
- Time-resolved imaging of current density at inlaid disk electrodesJournal of Electroanalytical Chemistry and Interfacial Electrochemistry, 1990
- Current Density Profiles of Surface Mounted and Recessed Electrodes for Neural ProsthesesIEEE Transactions on Biomedical Engineering, 1987
- Current Distribution on a Rotating Disk below the Limiting CurrentJournal of the Electrochemical Society, 1966