Peripheral visual field shifts after intraocular lens implantation
Open Access
- 1 December 2023
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (12) , 1270-1274
Abstract
Purpose: To assess whether intraocular lens (IOL) implantation induces shifts in the peripheral visual field. Setting: Department of Ophthalmology, Leiden University Medical Center, Leiden, the Netherlands. Design: Ray-tracing study. Methods: Nonsequential ray-tracing simulations were performed with phakic and pseudophakic versions of the same eye model to assess potential shifts in the visual field after IOL implantation. 2 different IOL designs were evaluated and for each design 5 different axial positions and 7 different intrinsic powers were tested. The relation between the physical position of the light source and the location where the retina was illuminated was determined for each eye model. Subsequently, these relations were used to calculate whether the visual field shifts in pseudophakic eyes. Results: The pseudophakic visual field shift was below 1 degree for central vision in all evaluated models. For peripheral vision, the light rays in the pseudophakic eyes were refracted to a more central retinal location compared with phakic eyes, resulting in a central shift of the peripheral visual field. The magnitude of the shift depended on the IOL design and its axial position, but could be as high as 5.4 degrees towards central vision. Conclusions: IOL implantation tends to have little effect on the central visual field but can induce an over 5 degrees shift in the peripheral visual field. Such a shift can affect the perception of peripheral visual complaints.Keywords
This publication has 33 references indexed in Scilit:
- Successful treatment of negative dysphotopsia with in-the-bag intraocular lens exchange using a wide ovoid IOLJournal of Cataract & Refractive Surgery, 2016
- Wide-field optical model of the human eye with asymmetrically tilted and decentered lens that reproduces measured ocular aberrationsOptica, 2015
- Comparison of the Optical Image Quality in the Periphery of Phakic and Pseudophakic EyesInvestigative Ophthalmology & Visual Science, 2013
- Customized eye models for determining optimized intraocular lenses powerBiomedical Optics Express, 2011
- Fast scanning peripheral wave-front sensor for the human eyeOptics Express, 2011
- Intraocular lens exchange in patients with negative dysphotopsia symptomsJournal of Cataract & Refractive Surgery, 2010
- Refractive index measurement of the isolated crystalline lens using optical coherence tomographyVision Research, 2008
- Instrument for measuring the misalignments of ocular surfacesOptics Express, 2006
- The Effect of Texturing the Intraocular Lens Edge on Postoperative Glare SymptomsArchives of Ophthalmology (1950), 2002
- Non-linear projection of the retinal image in a wide-angle schematic eye.British Journal of Ophthalmology, 1974