Impact of contact lens material and design on the ocular surface
- 1 March 2018
- journal article
- research article
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 101 (2) , 188-192
Abstract
To evaluate the impact on the ocular surface of a daily disposable hydrogel contact lens with high water content compared with two silicone hydrogel daily disposable lenses of lower water content. The hydrogel lens assessed was made from nesofilcon A and the silicone hydrogel lenses were made of delefilcon A and stenfilcon A. Contact lens thickness was measured to assess material stability during daily wear, and ocular surface parameters such as tear film osmolarity, tear meniscus area and central corneal thickness were also assessed. Optical quality was analysed for all cases by means of wavefront aberrometry. The nesofilcon A was shown to be the thinnest lens (p < 0.001), while no differences in lens thickness were found between the two silicone hydrogel lenses (p = 0.495). No significant differences were found in tear film osmolarity, tear meniscus area, central corneal thickness or corneal aberrations, either as a function of the lens measured or time of use (p > 0.05). In spite of having the thinnest lens and the highest water content, the hydrogel does not significantly impact on tear film and corneal swelling after one day of use in first-time wearers.Keywords
This publication has 24 references indexed in Scilit:
- New method for evaluation of early phase tear clearance by anterior segment optical coherence tomographyActa Ophthalmologica, 2013
- Optical Coherence Tomography for Measuring the Tear Film Meniscus: Correlation with Schirmer Test and Tear-Film Breakup TimeCurrent Eye Research, 2013
- OCT for Assessing Artificial Tears Effectiveness in Contact Lens WearersOptometry and Vision Science, 2012
- Measurement of the Time Course of Optical Quality and Visual Deterioration during Tear Break-UpInvestigative Ophthalmology & Visual Science, 2010
- Dynamic Contact Angle Analysis of Silicone Hydrogel Contact LensesJournal of Biomaterials Applications, 2010
- Wavefront Sensing and the Dynamics of Tear FilmCornea, 2007
- The Impact of Lipid on Contact Angle WettabilityOptometry and Vision Science, 2007
- Role of the tear film in the optical quality of the human eyeJournal of Cataract & Refractive Surgery, 2007
- Frequency of and Factors Associated With Contact Lens Dissatisfaction and DiscontinuationCornea, 2007
- Tear Film, Contact Lens, and Patient-Related Factors Associated with Contact Lens–Related Dry EyeInvestigative Ophthalmology & Visual Science, 2006