Final Results on the Nature of the Pulse-Height Spectrum from Semiconductor Detectors
Authors:
- 1 June 1972
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 19 (3) , 365-379
Abstract
An analysis of the shape of the pulse-height spectrum is carried out. The se quence of the physical processes which participate in shaping signals in a detector is taken into consideration. The main attention is paid to the charge collection process and to the spread in the amplitude Co(q) due to incomplete collection. A generalized analytical expression is obtained for the quantity q and the function Co(q) for detectors of the most widely used configurations (planar, coaxial, spherical). An analysis is given of the difference in two conventional approaches 6,8 to the problem of calculating the total pulse-height spectrum shape. It is noted that under ordinary conditions of gamma spectrometry the spectrum undergoes essential symmetrization due to multiple scattering (Compton scattering with subsequent photoabsorption). This brings the results of calculations outlined in refs. 6,8 closer to one another. However, in a single-step interaction (resulting, for instance, in the double escape peak) simple summation of dispersions for the spectrum components in 6 would lead to considerable errors. The scheme outlined in 8,12 is shown to permit using a pulse-heght analyzer in calculations of the spectrum shape. Presented in the Appendix are the results of an experiment showing that the signal across the detector electrodes is connected with potential differences traversed: Δq~Δv/v This relationship was used to calculate the charge q and the spectrum Co(q).Keywords
This publication has 9 references indexed in Scilit:
- Measurements of the Fano factor in germaniumNuclear Instruments and Methods, 1971
- Extension of Ramo's theorem as applied to induced charge in semiconductor detectorsNuclear Instruments and Methods, 1971
- The charge collection process in semiconductor radiation detectorsNuclear Instruments and Methods, 1970
- The effect of charge trapping on the spectrometer performance of p-i-n semiconductor detectorsNuclear Instruments and Methods, 1970
- The effects of carrier trapping in semiconductor gamma-ray spectrometersNuclear Instruments and Methods, 1969
- Ramo's theorem and the energy balance equations in evaluating the current pulse from semiconductor detectorsNuclear Instruments and Methods, 1969
- Use of collimated gamma-ray beams in the study of Ge(Li) detectorsNuclear Instruments and Methods, 1968
- Semiconductor detectors for nuclear spectrometry, INuclear Instruments and Methods, 1966
- On the induced charge in semiconductor detectorsNuclear Instruments and Methods, 1963