Restoration of low-dose digital breast tomosynthesis
- 19 April 2018
- journal article
- research article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (6) , 064003
Abstract
In breast cancer screening, the radiation dose must be kept to the minimum necessary to achieve the desired diagnostic objective, thus minimizing risks associated with cancer induction. However, decreasing the radiation dose also degrades the image quality. In this work we restore digital breast tomosynthesis (DBT) projections acquired at low radiation doses with the goal of achieving a quality comparable to that obtained from current standard full-dose imaging protocols. A multiframe denoising algorithm was applied to low-dose projections, which are filtered jointly. Furthermore, a weighted average was used to inject a varying portion of the noisy signal back into the denoised one, in order to attain a signal-to-noise ratio comparable to that of standard full-dose projections. The entire restoration framework leverages a signal-dependent noise model with quantum gain which varies both upon the projection angle and on the pixel position. A clinical DBT system and a 3D anthropomorphic breast phantom were used to validate the proposed method, both on DBT projections and slices from the 3D reconstructed volume. The framework is shown to attain the standard full-dose image quality from data acquired at 50% lower radiation dose, whereas progressive loss of relevant details compromises the image quality if the dosage is further decreased.Keywords
Funding Information
- Fundação de Amparo à Pesquisa do Estado de São Paulo (2013/18915-5)
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (88881.030443/2013-01)
- Luonnontieteiden ja Tekniikan Tutkimuksen Toimikunta (252547)
- Foundation for the National Institutes of Health (1R01CA154444)
- FP7 People: Marie-Curie Actions (607290)
- Susan G. Komen (IIRI326610)
- Burroughs Wellcome Fund (IRSA 1016451)
This publication has 32 references indexed in Scilit:
- Image quality of microcalcifications in digital breast tomosynthesis: Effects of projection-view distributionsMedical Physics, 2011
- Risk of Radiation-induced Breast Cancer from Mammographic ScreeningRadiology, 2011
- Applied Linear-Systems Theory2010
- X-Ray Production, Interaction, and Detection in Diagnostic Imaging2010
- Estimated Risk of Radiation-Induced Breast Cancer From Mammographic Screening for Young BRCA Mutation CarriersJNCI: Journal of the National Cancer Institute, 2009
- Noise removal using fourth-order partial differential equation with applications to medical magnetic resonance images in space and timeIEEE Transactions on Image Processing, 2003
- Low-Dose CT of the Abdomen: Evaluation of Image Improvement with Use of Noise Reduction Filters—Pilot StudyRadiology, 2003
- SCREEN-FILM AND DIGITAL MAMMOGRAPHYRadiologic Clinics of North America, 2000
- Variance stabilization1998
- Nonlinear anisotropic filtering of MRI dataIEEE Transactions on Medical Imaging, 1992