Cast versus splint in children with minimally angulated fractures of the distal radius: a randomized controlled trial
Authors:
- Kathy BoutisKBKathy Boutis
- Andrew WillanAWAndrew Willan
- Paul BabynPBPaul Babyn
- Ron GoereeRGRon Goeree
- Andrew HowardAHAndrew Howard
- 7 September 2010
- journal article
- research article
- Published by CMA Impact Inc. in Canadian Medical Association Journal
- Vol. 182 (14) , 1507-1512
Abstract
Background: Minimally angulated fractures of the distal radius are common in children and have excellent outcomes. We conducted a randomized controlled trial to determine whether the use of a prefabricated splint is as effective as a cast in the recovery of physical function. Methods: We included 96 children 5 to 12 years of age who were treated for a minimally angulated (≤ 15°) greenstick or transverse fracture of the wrist between April 2007 and September 2009 at a tertiary care pediatric hospital. Participants were randomly assigned to receive either a prefabricated wrist splint or a short arm cast for four weeks. The primary outcome was physical function at six weeks, measured using the performance version of the Activities Scale for Kids. Additional outcomes included the degree of angulation, range of motion, grip strength and complications. Results: Of the 96 children, 46 received a splint and 50 a cast. The mean Activities Scale for Kids score at six weeks was 92.8 in the splint group and 91.4 in the cast group (difference 1.44, 95% confidence interval [CI] −1.75 to 4.62). Thus, the null hypothesis that the splint is less effective by at least seven points was rejected. The between-group difference in angulation at four weeks was not statistically significant (9.85° in the splint group and 8.20° in the cast group; mean difference 1.65°, 95% CI −1.82° to 5.11°), nor was the between-group differences in range of motion, grip strength and complications. Interpretation: In children with minimally angulated fractures of the distal radius, use of a splint was as effective as a cast with respect to the recovery of physical function. In addition, the devices were comparable in terms of the maintenance of fracture stability and the occurrence of complications. (ClinicalTrials.gov trial register no. NCT00610220.)Keywords
This publication has 27 references indexed in Scilit:
- A Randomized Prospective Study of Music Therapy for Reducing Anxiety During Cast Room ProceduresJournal of Pediatric Orthopaedics, 2007
- Minimally angulated pediatric wrist fractures: Is immobilization without manipulation enough?Canadian Journal of Emergency Medicine, 2007
- A Randomized, Controlled Trial of Removable Splinting Versus Casting for Wrist Buckle Fractures in ChildrenPediatrics, 2006
- Above and Below-the-Elbow Plaster Casts for Distal Forearm Fractures in ChildrenA Randomized Controlled TrialJournal of Bone and Joint Surgery, 2006
- Principles of fracture remodeling in childrenInjury, 2005
- Effectiveness of ear protection in reducing anxiety during cast removal in children.2005
- The context of measuring disability: Does it matter whether capability or performance is measured?Journal of Clinical Epidemiology, 1996
- The role of children in reporting their physical disabilityArchives of Physical Medicine and Rehabilitation, 1995
- Test statistics and sample size formulae for comparative binomial trials with null hypothesis of non‐zero risk difference or non‐unity relative riskStatistics in Medicine, 1990
- The faces pain scale for the self-assessment of the severity of pain experienced by children: Development, initial validation, and preliminary investigation for ratio scale propertiesPain, 1990