Intraprocedural and Long‐Term Incomplete Occlusion of the Left Atrial Appendage Following Placement of the WATCHMAN Device: A Single Center Experience
Authors:
- Luigi DI BiaseLBLuigi DI Biase
- Prasant MohantyPMPrasant Mohanty
- Sanghamitra MohantySMSanghamitra Mohanty
- J. David BurkhardtJBJ. David Burkhardt
- 14 November 2011
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 23 (5) , 455-461
Abstract
Incomplete LAA Occlusion by WATCHMAN Device. Introduction: Transcatheter left atrial appendage (LAA) closure with the WATCHMAN device has become one of the therapeutic options in atrial fibrillation (AF) patients who are at high risk for ischemic stroke. However, the incidence and evolution of incomplete occlusion of the LAA during and after placement of the WATCHMAN device has not been reported.Methods and Results: Fifty‐eight consecutive patients who had undergone WATCHMAN device implant were included in the study. Intraprocedural, 45‐day and 12‐month transesophageal echocardiogram images were reviewed and analyzed. Peridevice gap was noted in 16 (27.6%), 17 (29.3%), and 20 (34.5%) patients across the 3 time points. Intraprocedural gaps are more likely to be persistent until 12 months and become larger in size over time. New gap also occurs during follow‐up even if the LAA was completely sealed at implantation. One patient had an ischemic stroke 4.7 months after implant; another patient developed a left atrial thrombus over the device 21.6 months after implant. Both patients had intraprocedural gap and discontinued warfarin therapy after the 45‐day evaluation.Conclusion: Incomplete LAA occlusion with a gap between the WATCHMAN device surface and the LAA wall is relatively common. Intraprocedural gaps are more likely to become bigger over time and persist, while new gaps also occur during follow‐up. Further studies are warranted to verify whether the presence and persistence of a peridevice gap is associated with increased risk of thromboembolic event in AF patients implanted with a WATCHMAN device. (J Cardiovasc Electrophysiol, Vol. 23, pp. 455‐461, May 2012)Keywords
This publication has 16 references indexed in Scilit:
- Thrombus formation after left atrial appendage exclusion using an amplatzer cardiac plug deviceCatheterization and Cardiovascular Interventions, 2011
- Left Atrial Appendage Closure in Atrial Fibrillation: A World without Anticoagulation?Cardiology Research and Practice, 2011
- Left Atrial Appendage Studied by Computed Tomography to Help Planning for Appendage Closure Device PlacementJournal of Cardiovascular Electrophysiology, 2010
- Left Atrial Appendage Occlusion Does Not Eliminate the Need for WarfarinCirculation, 2009
- Left Atrial Appendage Occlusion Eliminates the Need for WarfarinCirculation, 2009
- Risk of Stroke and Thrombus Formation From Delay Incontinence of a PLAATO‐Device in Friedreich AtaxiaClinical Cardiology, 2009
- Initial Worldwide Experience With the WATCHMAN Left Atrial Appendage System for Stroke Prevention in Atrial FibrillationJACC, 2007
- Embolic Events and Char Formation During Pulmonary Vein Isolation in Patients with Atrial Fibrillation: Impact of Different Anticoagulation Regimens and Importance of Intracardiac Echo ImagingJournal of Cardiovascular Electrophysiology, 2005
- Surgical left atrial appendage ligation is frequently incomplete: a transesophageal echocardiographic studyJACC, 2000
- Appendage obliteration to reduce stroke in cardiac surgical patients with atrial fibrillationThe Annals of Thoracic Surgery, 1996