We investigated a practical method to measure peak filling rate (PFR) as an indicator of diastolic function of the left ventricle. Ten adult volunteers underwent cine MR imaging using steady-state free precession (SSFP) and phase contrast (PC) sequences to measure PFR. Two PC image sets were acquired at the mitral valve orifice, and PFR was determined from the set with high true temporal resolution (temporal PC method) or with high spatial resolution (spatial PC method). SSFP images covering the left ventricle were acquired, and a time–volume curve was generated around the peak filling phase. PFR was determined using parabolic curve fitting on the first-derivative curve of the LV time–volume curve. PFR values estimated by the PC methods correlated well with those estimated by the SSFP method, despite apparent underestimation. The underestimation was smaller for the temporal PC method (12 %) than for the spatial PC method (28 %). Intra- and inter-observer repeatabilities were better for the PC methods than for the SSFP method. PFR measurement by PC imaging with high true temporal resolution is convenient and offers excellent repeatability and acceptable accuracy, indicating suitability for clinical use.Keywords
This publication has 16 references indexed in Scilit:
- Left ventricular diastolic function assessment from three‐dimensional three‐directional velocity‐encoded MRI with retrospective valve trackingJournal of Magnetic Resonance Imaging, 2011
- Diastology 2010: clinical approach to diastolic heart failureJournal of Echocardiography, 2010
- Heart Failure With Normal Ejection Fraction: The Complementary Roles of Echocardiography and CMR ImagingJACC: Cardiovascular Imaging, 2010
- Comparison of Magnetic Resonance Imaging Versus Doppler Echocardiography for the Evaluation of Left Ventricular Diastolic Function in Patients With Cardiac AmyloidosisThe American Journal of Cardiology, 2009
- Effect of intramyocardial bone marrow cell injection on diastolic function in patients with chronic myocardial ischemiaJournal of Magnetic Resonance Imaging, 2008
- Utility of Doppler Echocardiography and Tissue Doppler Imaging in the Estimation of Diastolic Function in Heart Failure With Normal Ejection FractionCirculation, 2007
- Diastolic Heart Failure Can Be Diagnosed by Comprehensive Two-Dimensional and Doppler EchocardiographyJACC, 2006
- Effect of temporal resolution on the estimation of left ventricular function by cardiac MR imagingMagnetic Resonance Imaging, 2005
- MR Imaging of the Heart with Cine True Fast Imaging with Steady-State Precession: Influence of Spatial and Temporal Resolutions on Left Ventricular Functional ParametersRadiology, 2002
- Diastolic heart failureCardiovascular Research, 2000