Comparative assessment of frictional forces between differently designed esthetic brackets during simulated canine retraction
Authors:
- 28 November 2022
- journal article
- research article
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 84 (SUPPL 3) , 1-9
Abstract
Objectives To evaluate force loss due to friction (FR) with an emphasis on esthetic brackets and their design differences during simulated canine retraction. Materials and methods The tested brackets were round and sharp-cornered conventional-ligating brackets and round-cornered self-ligating brackets. The tested archwires were stainless steel (0.018 × 0.025″ and 0.019 × 0.025″, and 0.018″) archwires. A total of 90 bracket–archwire combinations in 9 equally-sized groups (n = 10) were analyzed. Canine retraction was experimentally simulated in a biomechanical set-up utilizing the custom-made orthodontic measurement and simulation system (OMSS) using a NiTi coil spring that delivered a constant force of 1 N. The simulated retraction path was up to 4 mm. FR was compared among groups using the Welch t‑test. Significance level (α) was set to 0.05. Results The round-cornered conventional-ligating bracket exhibited the least FR (28.6 ± 5.4%), while there were no significant differences in FR between the round-cornered conventional-ligating bracket and the round-cornered self-ligating bracket with 0.018″ stainless steel wires. However, the round-cornered self-ligating bracket exhibited the least FR (34.9 ± 5.1% and 39.3 ± 4.6%) with 0.018 × 0.025″ and 0.019 × 0.025″ stainless steel archwires, respectively. The sharp-cornered conventional-ligating bracket showed the highest FR of 72.4 ± 3.0% among the bracket systems tested in this study. Conclusions The round-cornered conventional-ligating bracket showed less FR when compared to sharp-cornered conventional-ligating bracket. Conversely, the round-cornered conventional-ligating bracket exhibited greater FR when compared to the round-cornered self-ligating bracket, with an exception with respect to the 0.018″ wire. In general, FR increased with increased wire dimension.Keywords
This publication has 22 references indexed in Scilit:
- Friction and resistance to sliding in orthodontics: A critical reviewAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2009
- Comparison of frictional forces during the initial leveling stage in various combinations of self-ligating brackets and archwires with a custom-designed typodont systemAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2008
- Friction might increase anchorage loadingAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2007
- Resistance to sliding with 3 types of elastomeric modulesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2005
- Influence of angulation on the resistance to sliding in fixed appliancesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1999
- Friction between different wire-bracketconfigurations and materialsSeminars in Orthodontics, 1997
- A study of force application, amount of retarding force, and bracket width in sliding mechanicsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1996
- An experimental apparatus for the simulation of three-dimensional movements in orthodonticsJournal of Biomedical Engineering, 1992
- A comparative study of frictional forces between orthodontic brackets and arch wiresAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1991
- Application of the orthodontic measurement and simulation system (OMSS) in orthodonticsEuropean Journal of Orthodontics, 1991