Surgeon variability in total knee arthroplasty component alignment: a Monte Carlo analysis
- 13 February 2013
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (15) , 1738-1750
Abstract
Component mal-alignment in total knee arthroplasty has been associated with increased revision rates and poor clinical outcomes. A significant source of variability in traditional, jig-based total knee arthroplasty is the performance of the surgeon. The purpose of this study was to determine the most sensitive steps in the femoral and tibia arthroplasty procedures. A computational model of the total knee arthroplasty procedure was created, and Monte Carlo simulations were performed that included surgeon variability in each step of the procedure. The proportion of well-aligned components from the model agrees with clinical literature in most planes. When components must be aligned within ±3° in all planes, component alignment was most sensitive to the accuracy of identifying the lateral epicondyle for the femoral component, and to the precision of the transverse plane alignment of the extramedullary guide for the tibial component. This model can be used as a tool for evaluating different procedural approaches or sources of variability to improve the quality of the total knee arthroplasty procedure.Keywords
This publication has 29 references indexed in Scilit:
- Computer Navigation-assisted versus Minimally Invasive TKAClinical Orthopaedics and Related Research, 2008
- Imageless Navigation for TKA Increases Implantation AccuracyClinical Orthopaedics and Related Research, 2007
- Alignment of resection planes in total knee replacement obtained with the conventional technique, as assessed by a modern computer‐based navigation systemThe International Journal of Medical Robotics and Computer Assisted Surgery, 2007
- Projections of Primary and Revision Hip and Knee Arthroplasty in the United States from 2005 to 2030Journal of Bone and Joint Surgery, 2007
- Alignment and orientation of the components in total knee replacement with and without navigation supportThe Journal of Bone and Joint Surgery. British volume, 2007
- Economic Burden of Revision Hip and Knee Arthroplasty in Medicare EnrolleesClinical Orthopaedics and Related Research, 2006
- Projections of US prevalence of arthritis and associated activity limitationsArthritis & Rheumatism, 2005
- Alignment in total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2004
- OsiriX: An Open-Source Software for Navigating in Multidimensional DICOM ImagesJournal of Digital Imaging, 2004
- Tibial anatomy and functional axesJournal of Orthopaedic Research, 1989