Accurate blood peak velocity estimation using spectral models and vector doppler
- 14 April 2015
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 62 (4) , 686-696
Abstract
Ultrasound blood peak velocity estimates are routinely used for diagnostics, such as the grading of a stenosis. The peak velocity is typically assessed from the Doppler spectrum by locating the highest frequency detectable from noise. The selected frequency is then converted to velocity by the Doppler equation. This procedure contains several potential sources of error: the frequency selection is noise dependent and sensitive to the spectral broadening, which, in turn, is affected by the Doppler angle uncertainty. The result is, often, an inaccurate estimate. In this work we propose a new method that removes the aforementioned errors. The frequency is selected by exploiting a mathematical model of the Doppler spectrum that has recently been introduced. When a very large sample volume is used, which includes all the vessel section, the model is capable of predicting the exact threshold to be used without the need of broadening compensation. The angle ambiguity is solved by applying the threshold to the Doppler spectra measured from two different directions, according to the vector Doppler technique. The proposed approach has here been validated through Field II simulations, phantom experiments, and tests on volunteers by using defocused waves to insonify a large region from a linear array probe. A mean error lower than 1% and a mean coefficient of variability lower than 5% were measured in a variety of experimental conditions.Keywords
This publication has 33 references indexed in Scilit:
- Vector Projectile Imaging: Time-Resolved Dynamic Visualization of Complex Flow PatternsUltrasound in Medicine & Biology, 2014
- Finding the peak velocity in a flow from its doppler spectrumIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2013
- 2-D tracking doppler: a new method to limit spectral broadening in pulsed wave dopplerIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2013
- Effect of Velocity Profile Skewing on Blood Velocity and Volume Flow Waveforms Derived From Maximum Doppler Spectral VelocityUltrasound in Medicine & Biology, 2013
- Design and implementation of a smartphone-based portable ultrasound pulsed-wave doppler device for blood flow measurementIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2012
- Flow Patterns in Carotid Bifurcation Models Using Pulsed Doppler Ultrasound: Effect of Concentric vs. Eccentric Stenosis on Turbulence and RecirculationUltrasound in Medicine & Biology, 2010
- Accuracy and Reproducibility of a Novel Dual-Beam Vector Doppler MethodUltrasound in Medicine & Biology, 2009
- Human factors as a source of error in peak Doppler velocity measurementJournal of Vascular Surgery, 2005
- Interobserver variability of carotid Doppler peak velocity measurements among technologists in an ICAVL-accredited vascular laboratoryJournal of Vascular Surgery, 2004
- A comparison of single- and dual-beam methods for maximum velocity estimationUltrasound in Medicine & Biology, 1999