Validation and Interpretation of CALUX as a Tool for the Estimation of Dioxin-Like Activity in Marine Biological Matrixes
- 27 January 2005
- journal article
- research article
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 39 (6) , 1741-1748
Abstract
Among the different analytical tools proposed as an alternative to the very expensive gas chromatography high-resolution mass spectrometry (GC-HRMS) analyses of polychlorodibenzo-p-dioxin and polychlorodibenzofurans, Chemically Activated LUciferase gene eXpression (CALUX) in vitro cell bioassay is very promising. It allows the analyses of a high number of samples since it is relatively fast, inexpensive, and sensitive. However, this technique is not yet widely applied for screening or environmental monitoring. The main reasons are probably the lack of validation and the difficulty in interpreting the global biological response of the bioassay. In this paper, the strict quality control criteria set up for the validation of CALUX are described. The validation has shown good repeatability (relative standard deviation (RSD) = 9%) and good within-lab reproducibility (RSD = 15%) of the results. The quantification limit, in the conditions applied in this paper, is 1.25 pg CALUX-TEQ/g fat. Comparison of CALUX and GC-HRMS analysis was made for various marine matrixes (fishes, mussels, starfishes, sea birds, and marine mammals). Good correlations are usually observed, but there are systematic differences between the results. Attempts are made to identify the origin of the discrepancy between the two methods.Keywords
This publication has 16 references indexed in Scilit:
- Recombinant cell bioassay systems for the detection and relative quantitation of halogenated dioxins and related chemicalsTalanta, 2004
- Study of the interference problems of dioxin-like chemicals with the bio-analytical method CALUXTalanta, 2004
- Activation of the Aryl Hydrocarbon Receptor by Structurally Diverse Exogenous and Endogenous ChemicalsAnnual Review of Pharmacology and Toxicology, 2003
- Trace contamination with dioxin-like chemicals: evaluation of bioassay-based TEQ determination for hazard assessment and regulatory responsesEnvironmental Science & Policy, 2001
- Fast clean-up for polychlorinated dibenzo-p-dioxins, dibenzofurans and coplanar polychlorinated biphenyls analysis of high-fat-content biological samplesJournal of Chromatography A, 2001
- Toxic equivalency factors (TEFs) for PCBs, PCDDs, PCDFs for humans and wildlife.Environmental Health Perspectives, 1998
- The Ah Receptor: A Regulator of the Biochemical and Toxicological Actions of Structurally Diverse ChemicalsBulletin of Environmental Contamination and Toxicology, 1998
- Limitations of the toxic equivalency factor approach for risk assessment of TCDD and related compoundsTeratogenesis, Carcinogenesis, and Mutagenesis, 1997
- Species-Specific Recombinant Cell Lines as Bioassay Systems for the Detection of 2,3,7,8-Tetrachlorodibenzo-p-dioxin-like ChemicalsFundamental and Applied Toxicology, 1996
- Comparative Toxicology and Mechanism of Action of Polychlorinated Dibenzo-P-Dioxins and DibenzofuransAnnual Review of Pharmacology and Toxicology, 1986