Monitoring of Heart Rate from Photoplethysmographic Signals Using a Samsung Galaxy Note8 in Underwater Environments
Open Access
Abstract
Photoplethysmography (PPG) is a commonly used in determining heart rate and oxygen saturation (SpO2). However, PPG measurements and its accuracy are heavily affected by the measurement procedure and environmental factors such as light, temperature, and medium. In this paper, we analyzed the effects of different mediums (water vs. air) and temperature on the PPG signal quality and heart rate estimation. To evaluate the accuracy, we compared our measurement output with a gold-standard PPG device (NeXus-10 MKII). The experimental results show that the average PPG signal amplitude values of the underwater environment decreased considerably (22% decrease) compared to PPG signals of dry environments, and the heart rate measurement deviated 7% (5 beats per minute on average. The experimental results also show that the signal to noise ratio (SNR) and signal amplitude decrease as temperature decreases. Paired t-test which compares amplitude and heart rate values between the underwater and dry environments was performed and the test results show statistically significant differences for both amplitude and heart rate values (p < 0.05). Moreover, experimental results indicate that decreasing the temperature from 45 °C to 5 °C or changing the medium from air to water decreases PPG signal quality, (e.g., PPG signal amplitude decreases from 0.560 to 0.112). The heart rate is estimated within 5.06 bpm deviation at 18 °C in underwater environment, while estimation accuracy decreases as temperature goes down.Keywords
This publication has 31 references indexed in Scilit:
- Light Propagation with Phase Discontinuities: Generalized Laws of Reflection and RefractionScience, 2011
- Cardiovascular changes during underwater static and dynamic breath-hold dives in trained diversJournal of Applied Physiology, 2011
- Influence of Cold Water Immersion on Limb and Cutaneous Blood Flow at RestThe American Journal of Sports Medicine, 2011
- Comparison and reproducibility of sEMG during manual muscle testing on land and in waterJournal of Electromyography and Kinesiology, 2011
- Effect of Thermal Stress on Cardiac FunctionExercise and Sport Sciences Reviews, 2011
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007
- A comparison of muscle activity and heart rate response during backward and forward walking on an underwater treadmillGait & Posture, 2007
- Image Alignment and Stitching: A TutorialFoundations and Trends in Computer Graphics and Vision, 2007
- Surface EMG alterations induced by underwater recordingJournal of Electromyography and Kinesiology, 2004
- Effect of immersion, submersion, and scuba diving on heart rate variability: Figure 1British Journal of Sports Medicine, 2001