Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions*
Authors:
- Eric E. C. de WaalEWEric E. C. de Waal
- Steffen RexSRSteffen Rex
- Cas L. J. J. KruitwagenCKCas L. J. J. Kruitwagen
- Cor J. KalkmanCKCor J. Kalkman
- Wolfgang F. BuhreWBWolfgang F. Buhre
- 1 February 2009
- journal article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 37 (2) , 510-515
Abstract
Dynamic preload indicators like pulse pressure variation (PPV) and stroke volume variation (SVV) are increasingly being used for optimizing cardiac preload since they have been demonstrated to predict fluid responsiveness in a variety of perioperative settings. However, in open-chest conditions, the value of these indices has not been systematically examined yet. We, therefore, evaluated the ability of PPV and SVV to predict fluid responsiveness under open- and closed-chest conditions. Prospective, controlled, clinical study. University hospital. Twenty-two patients scheduled for elective coronary artery bypass graft surgery. Defined volume loads (VL) (10 mL kg−1 hydroxyethyl starch 6%) intra- and postoperatively. Stroke volume index was measured 1) before and after a VL intraoperatively in open-chest conditions, and 2) under closed-chest conditions within 1 hour after arrival in the intensive care unit. Central venous pressure and global end diastolic volume were assessed as static preload indicators. In addition, PPV and SVV (both obtained with PiCCO system) were recorded. Fluid-responders were defined by an increase in stroke volume index ≥12% subsequent to the VL. Receiver operating characteristic analysis showed that all preload indicators failed to predict fluid responsiveness in open-chest conditions. Under closed-chest conditions, the areas under the receiver operating characteristic curve for PPV and SVV were 0.884 (p = 0.004) and 0.911 (p = 0.003), respectively, whereas the static and volumetric preload parameters failed to predict fluid responsiveness. A PPV of ≥10% identified fluid-responders with a sensitivity of 64% and a specificity of 100%, while a SVV of >8% identified fluid-responders with a sensitivity of 100% and a specificity of 78%. Our results suggest that the dynamic preload indicators PPV and SVV are able to predict fluid responsiveness under closed-chest conditions, whereas all static and dynamic preload indicators fail to predict fluid responsiveness under open-chest conditions.Keywords
This publication has 35 references indexed in Scilit:
- Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge*Critical Care Medicine, 2007
- Invasive measures of left ventricular preloadCurrent Opinion in Critical Care, 2006
- Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiographyBritish Journal of Anaesthesia, 2005
- Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjectsCritical Care Medicine, 2004
- Global End-Diastolic Volume as an Indicator of Cardiac Preload in Patients With Septic Shock *Chest, 2003
- Intrathoracic blood volume index measured by thermodilution for preload monitoring after cardiac surgeryJournal of Cardiothoracic and Vascular Anesthesia, 2002
- Assessment of intrathoracic blood volume as an indicator of cardiac preload: Single transpulmonary thermodilution technique versus assessment of pressure preload parameters derived from a pulmonary artery catheterJournal of Cardiothoracic and Vascular Anesthesia, 2001
- Hemodynamic Monitoring by Double-Indicator Dilution Technique in Patients After Orthotopic Heart TransplantationChest, 2000
- Changes in central venous pressure and pulmonary capillary wedge pressure do not indicate changes in right and left heart volume in patients undergoing coronary artery bypass surgeryEuropean Journal of Anaesthesiology, 1999
- Misled by the Wedge?Chest, 1986