Incidence and indications for revision cochlear implant surgery in adults and children
Authors:
- 31 December 2008
- journal article
- research article
- Published by Wiley in The Laryngoscope
- Vol. 119 (1) , 152-157
Abstract
Objectives/Hypothesis: To identify the incidence of and common causes for cochlear implant revision.Study Design: Retrospective case series.Methods: Operative records were reviewed for all cases of revision cochlear implantation from 1992 to 2006. The causes for reimplantation were classified as hard device failure, soft device failure, exposure/infection, receiver/stimulator migration, and electrode migration. Manufacturers' failure analysis of explanted devices was likewise determined.Results: Eight hundred and six cochlear implants were performed during the study period including 44 (5.5%) revision procedures. The revision rate was 7.3% for children and 3.8% for adults and reached statistical significant difference. The most common reasons for revision were device failure (78%; 55% hard failure, 23% soft failure) followed by electrode migration (9%) and receiver/stimulator migration (7%). Manufacturers' analysis of failed devices revealed loss of hermetic seal and cracked cases to be the most common causes of failure. Bench analysis of 5/10 explanted devices that were soft failures demonstrated identifiable device defects.Conclusions: Revision cochlear implant surgery is an infrequent occurrence. Its incidence appears to be higher in children than in adults, although in this series does not appear to be due to increased wound complications, infections, or trauma. Explanted implants that have soft failure as the etiology may have demonstrable defects on bench testing. Laryngoscope, 119:152–157, 2009Keywords
This publication has 14 references indexed in Scilit:
- Revision Cochlear Implant Surgery in ChildrenOtology & Neurotology, 2008
- Infectious Complications in Pediatric Cochlear ImplantsThe Laryngoscope, 2007
- Cochlear Reimplantation: Causes of Failure, Outcomes, and Audiologic PerformanceThe Laryngoscope, 2007
- Revision surgeries in cochlear implant patients: a review of 45 casesEuropean Archives of Oto-Rhino-Laryngology, 2006
- Clinical Performance of Children Following Revision Surgery for a Cochlear ImplantOtolaryngology–Head and Neck Surgery, 2006
- Cochlear Implant Soft Failures Consensus Development Conference StatementOtology & Neurotology, 2005
- Revision Cochlear Implant Surgery: Causes and OutcomeOtolaryngology–Head and Neck Surgery, 2004
- Cochlear reimplantationThe Laryngoscope, 1999
- Audiologic Results following Reimplantation of Cochlear ImplantsAnnals of Otology, Rhinology & Laryngology, 1989
- Reimplantation of a Molded Scala Tympani Electrode: Impact on Psychophysical and Speech Discrimination AbilitiesAnnals of Otology, Rhinology & Laryngology, 1985