A numerical simulation tool for infrared thermopile detectors
Author:
- 1 January 2005
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10942734,p. 476-479
Abstract
A model for thermopile detectors is developed using a MatLab based numerical simulation. The model uses geometry and physical parameters of thermopile materials as input data and calculates the main characteristics of the detector. The numerical results closely agree with experimentally determined parameters. The influence of several input parameters on the detector's performance is studied. Using this approach the output signal of the Dexter Research ST150 detector is improved by 30%. A new model of a CMOS based detector for gas analysis is optimized. The simulation results show significant improvement in the detector's performance when poly-Si/Al materials are substituted by n-poly-Si/p-poly-Si materials. The model predicts D* = 2.5/spl times/10/sup 8/ cmHz/sup 1/2//W with a time constant of 17 ms.Keywords
This publication has 8 references indexed in Scilit:
- Thermal conductivity of doped polysilicon layersJournal of Microelectromechanical Systems, 2001
- Dynamic non-linear electro-thermal simulation of a thin-film thermal converterMicroelectronics Journal, 1999
- Optimal design and noise considerations of CMOS compatible IR thermoelectric sensorsSensors and Actuators A: Physical, 1998
- Uncooled thermopile infrared detector linear arrays with detectivity greater than 10/sup 9/ cmHz/sup 1/2//WIEEE Transactions on Electron Devices, 1998
- A 32-element micromachined thermal imager with on-chip multiplexingSensors and Actuators A: Physical, 1995
- Infrared thermopile sensors with high sensitivity and very low temperature coefficientSensors and Actuators A: Physical, 1995
- Optimization tool for the performance parameters of thermoelectric microsensorsSensors and Actuators A: Physical, 1993
- High-sensitivity radiation thermopiles made of BiSbTe filmsSensors and Actuators A: Physical, 1991