Rabbit Cornea Microstructure Response to Changes in Intraocular Pressure Visualized by Using Nonlinear Optical Microscopy
Authors:
- Alvin T YehAYAlvin T Yeh
- 1 February 2008
- journal article
- Published by Wolters Kluwer Health in Cornea
- Vol. 27 (2) , 202-208
Abstract
To characterize the microstructural response of the rabbit cornea to changes in intraocular pressure (IOP) by using nonlinear optical microscopy (NLOM). Isolated rabbit corneas were mounted on an artificial anterior chamber in series with a manometer and were hydrostatically pressurized by a reservoir. The chamber was mounted on an upright microscope stage of a custom-built NLOM system for corneal imaging without using exogenous stains or dyes. Second harmonic generation in collagen was used to image through the full thickness of the central corneal stroma at IOPs between 5 and 20 mm Hg. Microstructural morphology changes as a function of IOP were used to characterize the depth-dependent response of the central cornea. Regional collagen lamellae architecture through the full thickness of the stroma was specifically imaged as a function of IOP. Hypotensive corneas showed gaps between lamellar structures that decreased in size with increasing IOP. These morphologic features appear to result from interwoven lamellae oriented along the anterior-posterior axis and parallel to the cornea surface. They appear throughout the full thickness and disappear with tension in the anterior but persist in the posterior central cornea, even at hypertensive IOP. NLOM reveals interwoven collagen lamellae sheets through the full thickness of the rabbit central cornea oriented along the anterior-posterior axis and parallel to the surface. The nondestructive nature of NLOM allows 3-dimensional imaging of stromal architecture as a function of IOP in situ. Collagen morphologic features were used as an indirect measure of depth-dependent mechanical response to changes in IOP.Keywords
This publication has 29 references indexed in Scilit:
- Noninvasive corneal stromal collagen imaging using two-photon-generated second-harmonic signalsJournal of Cataract & Refractive Surgery, 2006
- The specific architecture of the anterior stroma accounts for maintenance of corneal curvatureBritish Journal of Ophthalmology, 2001
- Three-dimensional confocal microscopy of the living in situ rabbit corneaOptics Express, 1998
- Epithelial and corneal thickness measurements by in vivo confocal microscopy through focusing (CMTF)Current Eye Research, 1997
- Regional elastic performance of the human corneaJournal of Biomechanics, 1996
- Three‐dimensionally resolved NAD(P)H cellular metabolic redox imaging of the in situ cornea with two‐photon excitation laser scanning microscopyJournal of Microscopy, 1995
- A quantitative evaluation of Fourier components in transparent and opaque calf corneaJournal of Anatomy, 1991
- The organisation of collagen fibrils in the human corneal stroma: A synchrotron X-ray diffraction studyCurrent Eye Research, 1987
- The mechanical properties of the rabbit and human corneaJournal of Biomechanics, 1986
- Observations on the human cornea in vitroExperimental Eye Research, 1981