Comparison of outcomes following end-to-end hand-sewn and mechanical oesophagogastric anastomosis after oesophagectomy for carcinoma: a prospective randomized controlled trial
Authors:
Open Access
- 4 December 2014
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 47 (3) , e118-e123
Abstract
The effects of the use of the stapler or hand-sewn method in oesophagogastric anastomosis on postoperative morbidity, mortality and quality of life after oesophagectomy remain controversial. The purpose of his study was to compare clinical outcomes of hand-sewn and stapler techniques in oesophagogastric anastomosis after oesophagectomy for oesophageal carcinoma. We performed a prospective randomized controlled trial on 478 patients treated for oesophageal tumour between February 2009 and December 2011. Patients were randomly assigned to two treatment groups with 237 patients in the hand-sewn group and 241 patients in the circular stapler group (http://www.chictr.org: ChiCTR-TRC-13004428). The mean follow-up time was 18 months. The mean operating time of the stapled group and the hand-sewn group were 193 and 226 min, respectively (P < 0.001). Seventeen clinical and radiological leakages occurred in the hand-sewn group compared with 7 in the stapler group (P = 0.033). In the stapler group hospital mortality occurred in 10 patients (4.3%) and in the hand-sewn group in 9 patients (3.9%) (P = 0.837). Anastomotic strictures were noted in 31 patients from the stapler group (14.2%) and in 16 patients from the hand-sewn group (7.5%) (P = 0.027). Using the circular stapler method in oesophagogastric anastomoses had a lower anastomotic leakage rate and shorter operating time compared with the hand-sewn method. However, the circular stapler method was associated with a significantly increased risk of anastomotic strictures.Keywords
This publication has 16 references indexed in Scilit:
- A Prospective Randomized Controlled Trial of Semi‐mechanical versus Hand‐sewn or Circular Stapled Esophagogastrostomy for Prevention of Anastomotic StrictureWorld Journal of Surgery, 2013
- CONSORT 2010 Statement: Updated Guidelines for Reporting Parallel Group Randomized TrialsAnnals of Internal Medicine, 2010
- 7th Edition of the AJCC Cancer Staging Manual: Esophagus and Esophagogastric JunctionAnnals of Surgical Oncology, 2010
- The management of esophagogastric anastomotic leak after esophagectomy for esophageal carcinomaDiseases of the Esophagus, 2009
- Hand-Sewn Cervical Anastomosis Versus Stapled Intrathoracic Anastomosis After Esophagectomy for Middle or Lower Thoracic Esophageal Cancer: A Prospective Randomized Controlled StudySurgery Today, 2007
- Comparison of manual and mechanical cervical esophagogastric anastomosis after esophageal resection for squamous cell carcinoma: a prospective randomized controlled trialEuropean Journal of Cardio-Thoracic Surgery, 2004
- Cervical or Thoracic Anastomosis After Esophageal Resection and Gastric Tube ReconstructionAnnals of Surgery, 2003
- Improvement in the Results of Surgical Treatment of Advanced Squamous Esophageal Carcinoma During 15 Consecutive YearsAnnals of Surgery, 2000
- Comparison of Hand-Sewn and Stapled Esophagogastric Anastomosis After Esophageal Resection for CancerAnnals of Surgery, 1997
- Esophagogastrostomy anastomotic leaks complicating esophagectomy: A reviewThe American Journal of Surgery, 1995