Internal fixation of humeral shaft fractures using minimally invasive plating: comparative study of two implants
Authors:
- 5 July 2012
- journal article
- research article
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 23 (5) , 527-534
Abstract
We compared the results of two types of implants, dynamic compression plates (DCPs) and locking compression plates (LCPs), applied to correct mid-distal third humeral shaft fractures using minimally invasive plating osteosynthesis (MIPO). Data of 43 patients with mid-distal third humeral shaft fractures treated using MIPO were retrospectively analyzed. Patients were divided into two groups according to the implants applied: group A (n = 26), those whose fractures were fixed with 4.5-mm DCP, and group B (n = 17) fixed with 4.5-mm LCP or metaphyseal LCP. The outcomes of the two groups in terms of operative time, time of fracture union, occurrence of early and late postoperative complications, University of California—Los Angeles (UCLA) End-Result score and the Mayo Elbow Performance Index (MEPI) were compared. The mean operative time was 107.8 ± 33.1 min in group A and 91.2 ± 40.4 min in group B (p > 0.05). The mean time of fracture union was 16.77 ± 6.01 weeks in group A and 14.59 ± 5.73 weeks in group B (p > 0.05). Seven (26.9 %) patients had postoperative complications in group A and 3 (17.6 %) in group B (p > 0.05). The mean UCLA End-Result score in group A was 34.31 ± 1.26 points and 33.12 ± 2.76 points in group B (p > 0.05). The mean MEPI was 100.00 ± 0.00 points in group A and 97.35 ± 7.52 points in group B (p > 0.05). In surgical stabilization of mid-distal humeral shaft fractures using MIPO, application of DCP or LCP resulted in good outcomes, there were no significant differences between the outcomes of these two types of implant.Keywords
This publication has 27 references indexed in Scilit:
- Minimally invasive plate osteosynthesis for humerus diaphyseal fracturesIndian Journal of Orthopaedics, 2011
- Early Full Range of Shoulder and Elbow Motion is Possible After Minimally Invasive Plate Osteosynthesis for Humeral Shaft FracturesJournal of Orthopaedic Trauma, 2010
- Minimally invasive plate osteosynthesis for humeral shaft fractures: are results reproducible?International Orthopaedics, 2009
- Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction techniqueInternational Orthopaedics, 2009
- Are Locking Screws Advantageous with Plate Fixation of Humeral Shaft Fractures? A Biomechanical Analysis of Synthetic and Cadaveric BoneJournal of Orthopaedic Trauma, 2008
- Is MIPO in humeral shaft fractures really safe? Postoperative ultrasonographic evaluationInternational Orthopaedics, 2008
- A Mechanical Comparison of the Locking Compression Plate (LCP) and the Low Contact-Dynamic Compression Plate (DCP) in an Osteoporotic Bone ModelJournal of Orthopaedic Trauma, 2008
- Percutaneous Plating of the Humerus With Locked Plating: Technique and Case ReportJournal of Trauma: Injury, Infection & Critical Care, 2007
- Fractures of the distal third of the humerus with palsy of the radial nerveThe Journal of Bone and Joint Surgery. British volume, 2006
- Percutaneous Fixation of Comminuted Fractures of the Humerus: Initial Experience at Al Razi Hospital, KuwaitMedical Principles and Practice, 2006