Simultaneous acquisition of gradient echo/spin echo BOLD and perfusion with a separate labeling coil
- 20 July 2010
- journal article
- review article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 64 (6) , 1827-1831
Abstract
Arterial spin labeling-based cerebral blood flow imaging complements blood oxygenation level dependent (BOLD) imaging with a measure that is more quantitative and has better specificity to neuronal activation. Relative to gradient echo BOLD, spin echo BOLD has better spatial specificity because it is less biased to large draining veins. Although there have been many studies comparing simultaneously acquired cerebral blood flow data with gradient echo BOLD data in fMRI, there have been few studies comparing cerebral blood flow with SE BOLD and no study comparing all three. We present a pulse sequence that simultaneously acquires cerebral blood flow data with a separate labeling coil, gradient echo BOLD, and spin echo BOLD images. Simultaneous acquisition avoids interscan variability, allowing more direct assessment and comparison of each contrast's relative specificity and reproducibility. Furthermore, it facilitates studies that may benefit from multiple complementary measures.Keywords
Funding Information
- NIH (RO1 EB002009)
This publication has 19 references indexed in Scilit:
- An inexpensive and programmable RF transmitter setup for two‐coil CASLConcepts in Magnetic Resonance Part B, 2008
- Quantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 TeslaMagnetic Resonance in Medicine, 2005
- Quantitative assessment of the reproducibility of functional activation measured with BOLD and MR perfusion imaging: Implications for clinical trial designNeuroImage, 2005
- Whole‐brain 3D perfusion MRI at 3.0 T using CASL with a separate labeling coilMagnetic Resonance in Medicine, 2004
- High‐resolution, spin‐echo BOLD, and CBF fMRI at 4 and 7 TMagnetic Resonance in Medicine, 2002
- An Investigation of the Value of Spin-Echo-Based fMRI Using a Stroop Color–Word Matching Task and EPI at 3 TNeuroImage, 2002
- Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency.Radiology, 1994
- Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical modelBiophysical Journal, 1993
- Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging.Proceedings of the National Academy of Sciences, 1992
- Perfusion imagingMagnetic Resonance in Medicine, 1992