Efficiency analysis on the inverter using the energy-saving lamp
Authors:
Open Access
- 1 November 2019
- conference paper
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 674 (1) , 012034
Abstract
Electric energy savings are influenced by magnitude of reactive power used by electric customers, one of the tools that can minimize reactive power is the inverter, which is an electronic equipment, that can change the direct current of electricity to alternating current, The method used is by measuring along with analysis of calculation each time the inverter is given the burden of energy-saving lamps with varying power to determine the change in the electrical quantities to be analyzed. Inverter efficiency in doing the convert direct current to alternating current during low load (5W) amounted to 94.66%, and the highest load current (203W) amounted to 90.55%.Keywords
This publication has 3 references indexed in Scilit:
- Review and comparative study of single-stage inverters for a PV systemRenewable and Sustainable Energy Reviews, 2018
- Energy Efficiency 20172017
- Reactive power pricing and managementIEEE Transactions on Power Systems, 1997