Abstract
A break at pH 6.2–6.3 was observed recently in the linear titration curve of the buffer used in the double buffer method (Yuan, 1974). As a result, different pH‐acidity relationships above and below this pH would have to be used in the lime requirement calculation. An attempt was made to investigate the possible cause or causes for the break. Suspected contamination of Cr 2 O 7 2‐ in the K 2 C r O 4 reagent originally used in the development of the method was investigated as was the effect of CaCl 2 on buffering behavior of CrO 4 2‐ . Although a completely satisfactory explanation of the anomaly was not obtained, it appears that higher purity of currently available K 2 C r O 4 is involved. A modification of the buffer composition was made to give a linear curve with currently available chemicals so that the soil lime requirement can be more easily calculated. A table to show the soil buffering capacity based on a linear 1:1 pH‐acidity relationship has also been added.