Primary stability of rotator cuff repair: can more suture materials yield more strength?
Authors:
- 7 October 2015
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 40 (5) , 989-997
Abstract
Introduction It remains unclear if the increased biomechanical stability of the double-row repair is solely a result of the technique itself or due to the greater number of utilized materials. This study analyses the various rotator cuff (RC) repair interfaces and the influence of doubling the number of suture knots, stitch techniques and suture anchors on the primary stability of the RC reconstruction. Materials and methods Established cyclic testing protocols were used to test the primary stability of the knot interface with a Duncan loop and Roeder knot, the tendon-to-suture interface with a single-stitch and Mason-Allen-stitch and the anchor-to-bone interface with OPUS Magnum 2® and BioCorkscrew® anchors. After doubling the materials, the interfaces were tested again and compared to the yielded solitary values. The maximum failure loads (Fmax), clinical failure (CF), system displacement (SD) and modes of failure were recorded. Results Doubling the amount of knots, stitches and suture anchors improved almost all interface parameters. For example, Fmax, CF and SD of the Roeder knot could be significantly improved from 142.5 N to 256.7 N, from 82.5 N to 155.0 N and from 0.45 mm to 0.20 mm, respectively. The Mason-Allen stitch’s Fmax improved from 196.4 N to 324.9 N, and CF from 94.25 N to 139.8 N, with almost identical SD of 0.81 mm and 0.84 mm. Bio-Corkscrew® Fmax improved from 232.5 N to 317.5 N, CF from 182.5 N to 210 N, and SD from 0.85 mm to 0.64 mm. Conclusion Doubling the number of knots, stitches and suture anchors increases the primary stability of the various RC repair interfaces and may result in RC rerupture rate reduction. Furthermore, this study suggests that a suture anchor loaded with two or three sutures may yield the same primary stability as two or three suture anchors loaded with a single suture. This in vitro biomechanical study focuses solely on the rotator cuff interfaces at time zero; the biological healing process was therefore not analysed and requires further investigation. Clinical relevance Improved primary stability by increased number of suture materials may reduce rate of RC rerupture.Keywords
This publication has 31 references indexed in Scilit:
- A systematic review and pooled analysis of the prevalence of rotator cuff disease with increasing ageJournal of Shoulder and Elbow Surgery, 2014
- Clinical and structural outcomes after arthroscopic single-row versus double-row rotator cuff repair: a systematic review and meta-analysis of level I randomized clinical trialsJournal of Shoulder and Elbow Surgery, 2014
- Single-row, double-row, and transosseous equivalent techniques for isolated supraspinatus tendon tears with minimal atrophy: A retrospective comparative outcome and radiographic analysis at minimum 2-year followupInternational Journal of Shoulder Surgery, 2014
- A Multicenter Randomized Controlled Trial Comparing Single-Row with Double-Row Fixation in Arthroscopic Rotator Cuff RepairJournal of Bone and Joint Surgery, 2012
- A Prospective Randomized Clinical Trial Comparing Arthroscopic Single-and Double-Row Rotator Cuff RepairThe American Journal of Sports Medicine, 2009
- Clinical Evidence Shows No Difference Between Single‐ and Double‐Row Repair for Rotator Cuff TearsArthroscopy, 2007
- Repair Integrity and Functional Outcome After Arthroscopic Double-Row Rotator Cuff RepairJournal of Bone and Joint Surgery, 2007
- Rotator cuff repair: The effect of double-row fixation on three-dimensional repair siteJournal of Shoulder and Elbow Surgery, 2006
- Arthroscopic knots: Determining the optimal balance of loop security and knot securityArthroscopy, 2004
- The Effect of Comorbidity on Self-Assessed Function in Patients with a Chronic Rotator Cuff TearJournal of Bone and Joint Surgery, 2004