Microhardness studies on the setting characteristics of fissure sealants
Authors:
- 1 April 1978
- journal article
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 5 (2) , 187-195
Abstract
The hardness of five fissure sealants was measured using a Wallace Microhardness Tester and found to continue to increase long after the initial setting. The effect of the intensity of radiation and exposure time on the setting of two u.v. activated sealants (Nuva-seal and Alphaseal) was also investigated, with higher intensities producing both a more rapid set and greater final hardness. Alphaseal required longer exposure at a given intensity of u.v. radiation to achieve the same hardness as Nuva-seal, and displayed relatively slow setting in depth, which could give rise to incomplete polymerization during clinical use, resulting in early sealant loss. Thus special care must be taken to ensure that Alphaseal receives an adequate exposure to u.v. radiation, and sources which are suitable for setting Nuva-seal may not be sufficiently powerful when applying Alphaseal.Keywords
This publication has 8 references indexed in Scilit:
- The performance of ultraviolet lights used to polymerize fissure sealantsJournal of Oral Rehabilitation, 1977
- Fissure sealing by practitioners. First year retention data in Scottish 6-year-old childrenBritish Dental Journal, 1976
- The surface hardness of three bisphenol A and glycidyl methacrylate fissure sealantsJournal of Dentistry, 1975
- A comparative evaluation of the microhardness, water solubility and water absorption of fissure sealantsJournal of Dentistry, 1975
- The use of ultra-violet radiation in dentistryBritish Dental Journal, 1974
- Fissure sealants. Further results of clinical trialsBritish Dental Journal, 1974
- Fissure SealantsCaries Research, 1974
- Adhesive Sealing of Pits and Fissures for Caries Prevention, With Use of Ultraviolet LightThe Journal of the American Dental Association, 1970