Kinetic-Energy Discrimination for Atom Probe Tomography
- 19 January 2011
- journal article
- atom probe-applications
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 17 (1) , 1-14
Abstract
The benefits of using kinetic-energy information to aid ion discrimination in atom probe tomography (APT) are explored. Ion peak interferences in time-of-flight (TOF) mass spectra are categorized by difficulty of discrimination using TOF and kinetic-energy information. Several of these categories, which are intractable interferences when only TOF information is available, may be discriminated when kinetic-energy information also is available. Furthermore, many opportunities for removing noise from composition determinations and three-dimensional images are enabled. Modest kinetic-energy resolving powers (KRPs) of 10 or so should be sufficient to have a major impact on APT. With KRP of about 100, the energy deficits in voltage pulsing may be resolved to enable peak discrimination in straight-flight-path instruments. Real examples and simulated mass spectra are used to illustrate the benefits of kinetic-energy discrimination. Many of the conclusions are applicable generally in TOF spectroscopy. Current detectors do not provide the kinetic energy of incoming ions, but there are realistic prospects for building such detectors and these are discussed. A program to develop these detectors should be pursued.Keywords
This publication has 24 references indexed in Scilit:
- Correlated ion analysis and the interpretation of atom probe mass spectraUltramicroscopy, 2011
- Time-of-Flight Mass Spectrometry With Latching Nb Meander DetectorsIEEE Transactions on Applied Superconductivity, 2009
- Analysis of Bulk Dielectrics with Atom Probe TomographyMicroscopy and Microanalysis, 2008
- Advances in Pulsed-Laser Atom Probe: Instrument and Specimen Design for Optimum PerformanceMicroscopy and Microanalysis, 2007
- Seeing with SuperconductorsScientific American, 2006
- The characteristic electron–phonon coupling time of unconventional superconductors and implications for optical detectorsSuperconductor Science and Technology, 2005
- Effects of Spatial Nonuniformity of Superconducting-Tunnel-Junction Ion Detectors on Mass SpectroscopyIEEE Transactions on Applied Superconductivity, 2005
- First Data from a Commercial Local Electrode Atom Probe (LEAP)Microscopy and Microanalysis, 2004
- Performance of a microsphere plate electron multiplier in APFIM applicationsUltramicroscopy, 1999
- APFIM 200 — A reflectron-based atom probeSurface Science, 1992