The Relaxometer: A complete and comprehensive computer-controlled neuromuscular transmission measurement system developed for clinical research on muscle relaxants
Authors:
- 1 January 1993
- journal article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 9 (1) , 38-44
Abstract
The Relaxometer is a computer-controlled system developed for reliable clinical experimental measurements on neuromuscular block. This system is based on an adapted personal computer (Atari 1040 ST) with a monochrome monitor (Atari SM 124), and a microcomputer-driven slave unit (stimulator). There are several stimulation patterns available: single twitch at 0.1 and 1 Hz, single train-of-four, continuous train-of-four every 12 seconds, and tetanic stimulation at 50 Hz for 5 seconds followed by posttetanic count. The system is equipped with a temperature module for continuous monitoring of the skin/muscle temperature and a rechargeable battery to allow uninterrupted measurements if the apparatus is disconnected from the line power. All acquired data, computer-calculated parameters (onset time, duration time, recovery index, train-of-four ratio, tetanic fade, and posttetanic count), and the mechanomyogram are presented on screen continuously, are stored on floppy disk, and can be printed in a well-organized format.Keywords
This publication has 26 references indexed in Scilit:
- Intubating conditions and onset of neuromuscular block of rocuronium (Org 9426); a comparison with suxamethoniumActa Anaesthesiologica Scandinavica, 1992
- Twitch tension and train‐of‐four ratio during prolonged neuromuscular monitoring at different peripheral temperaturesActa Anaesthesiologica Scandinavica, 1991
- The Relationship Between Adductor Pollicis Twitch Tension and Core, Skin, and Muscle Temperature during Nitrous Oxide—Isoflurane Anesthesia in HumansAnesthesiology, 1989
- Clinical assessment of a new neuromuscular transmission monitoring system (ACCELOGRAPH®)Journal of Anesthesia, 1989
- The Accelograph®: a new neuromuscular transmission monitorActa Anaesthesiologica Scandinavica, 1988
- The effect of temperature, ischaemia and contractile activity on the relaxation rate of human muscleClinical Physiology and Functional Imaging, 1982
- A Recording System for Continuous Evoked ElectromyogrophyAnesthesiology, 1973
- A Means of Recording Force of Thumb AdductionAnesthesiology, 1968
- Comparison of Electrical and Mechanical Recording of Spontaneous and Evoked Muscle ActivityAnesthesiology, 1965
- A Portable Peripheral Nerve-StimulatorAnesthesiology, 1965