Fast 3D Super-Resolution Ultrasound With Adaptive Weight-Based Beamforming
Authors:
- Jipeng YanJYJipeng Yan
- Bingxue WangBWBingxue Wang
- Kai RiemerKRKai Riemer
- Joseph Hansen-ShearerJHJoseph Hansen-Shearer
- Marcelo LerendeguiMLMarcelo Lerendegui
- Matthieu ToulemondeMTMatthieu Toulemonde
- Christopher J RowlandsCRChristopher J Rowlands
- Peter D. WeinbergPWPeter D. Weinberg
- Meng-Xing TangMTMeng-Xing Tang
Open Access
- 30 March 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (9) , 2752-2761
Abstract
Objective: Super-resolution ultrasound (SRUS) imaging through localising and tracking sparse microbubbles has been shown to reveal microvascular structure and flow beyond the wave diffraction limit. Most SRUS studies use standard delay and sum (DAS) beamforming, where high side lobes and broad main lobes make isolation and localisation of densely distributed bubbles challenging, particularly in 3D due to the typically small aperture of matrix array probes. Method: This study aimed to improve 3D SRUS by implementing a new fast 3D coherence beamformer based on channel signal variance. Two additional fast coherence beamformers, that have been implemented in 2D were implemented in 3D for the first time as comparison: a nonlinear beamformer with p -th root compression and a coherence factor beamformer. The 3D coherence beamformers, together with DAS, were compared in computer simulation, on a microflow phantom and in vivo . Results: Simulation results demonstrated that all three adaptive weight-based beamformers can narrow the main lobe, suppress the side lobes, while maintaining the weaker scatter signals. Improved 3D SRUS images of microflow phantom and a rabbit kidney within a 3-second acquisition were obtained using the adaptive weight-based beamformers, when compared with DAS. Conclusion: The adaptive weight-based 3D beamformers can improve the SRUS and the proposed variance-based beamformer performs best in simulations and experiments. Significance: Fast 3D SRUS would significantly enhance the potential utility of this emerging imaging modality in a broad range of biomedical applications.Keywords
All Related Versions
Funding Information
- Chan Zuckerberg Initiative (2020-225443)
- EPSRC Impact Acceleration Account Funding (EP/R511547/1)
- MRC Confidence in Concept scheme at Imperial College (MC-PC-18050)
- Engineering and Physical Sciences Research Council (EP/T008970/1)
- National Institute for Health Research i4i (NIHR200972)
This publication has 47 references indexed in Scilit:
- Ultrafast ultrasound localization microscopy for deep super-resolution vascular imagingNature, 2015
- Detection and Tracking of Multiple Microbubbles in Ultrasound B-Mode ImagesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2015
- Quantifying Activation of Perfluorocarbon-Based Phase-Change Contrast Agents Using Simultaneous Acoustic and Optical ObservationUltrasound in Medicine & Biology, 2015
- The Delay Multiply and Sum Beamforming Algorithm in Ultrasound B-Mode Medical ImagingIEEE Transactions on Medical Imaging, 2014
- In Vivo Acoustic Super-Resolution and Super-Resolved Velocity Mapping Using MicrobubblesIEEE Transactions on Medical Imaging, 2014
- 3D ultrafast ultrasound imagingin vivoPhysics in Medicine & Biology, 2014
- Acoustic super-resolution with ultrasound and microbubblesPhysics in Medicine & Biology, 2013
- 3-D ultrasound imaging performance of a row-column addressed 2-D array transducer: A measurement study2013
- Imaging tumor vascularity by tracing single microbubbles2011
- Short-lag spatial coherence of backscattered echoes: imaging characteristicsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2011